§ 30-101 — General standards for all zones
Code of Ordinances, City of Olive Branch, Mississippi (Supp. No. 14: codified through Ordinance of June 17, 2025) · Olive Branch Code of Ordinances § 30-101
Corpus is an independent public-information project, not the official City of Olive Branch website. Stable reference: corpuslaw.us/code/063da29c-91cf-4b1e-b9b6-0160b8dc2e29
Sec. 30-101. - General standards for all zones.
In all areas of special flood hazard the following provisions are required: (1) New construction and substantial improvements shall be anchored to prevent flotation, collapse and lateral movement of the structure. (2) Manufactured homes shall be anchored to prevent flotation, collapse, and lateral movement. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors. Dry stacked blocks (stacked without the use of mortar or cement to bond them together) are not to be used as an anchor/elevation method. This standard shall be in addition to and consistent with applicable state requirements for resisting wind forces. (3) New construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage. (4) New construction or substantial improvements shall be constructed by methods and practices that minimize flood damage. (5) Electrical, heating, ventilation, plumbing, air conditioning equipment and other service facilities shall be designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding, such facilities shall be located a minimum of two feet above the base flood elevation. (6) New and replacement water supply systems shall be designed to minimize or eliminate infiltration of flood waters into the system. (7) New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of flood waters into the systems and discharges from the systems into flood waters. (8) On-site waste disposal systems shall be located and constructed to avoid impairment to them or contamination from them during flooding. (9) Any alteration, repair, reconstruction or improvements to a building that is in compliance with the provisions of this article shall meet the requirements of new construction as contained in this article. (10) Any alteration, repair, reconstruction or improvements to a building that is not in compliance with the provisions of this article, shall be undertaken only if said non-conformity shall meet the requirements of "new construction" as contained in this article. (11) All gas and liquid storage tanks (both above and below ground) shall be adequately anchored to prevent floatation, lateral movement resulting from hydrodynamic forces, and the effects of buoyancy. (12) When new construction and substantial improvements are located in multiple flood zones or in a flood zone with multiple base flood elevations, they shall meet the requirement for the more stringent flood zone and the highest base flood elevation. (13) Require that all manufactured homes be placed or installed using methods and practices which minimize flood damage. Manufactured homes must be elevated and anchored to resist flotation, collapse, or lateral movement. Dry stacked blocks (stacked without the use of mortar or cement to bond them together) are not allowed within the special flood hazard area.
(Ord of 8-16-2022(1), § V)
Ask a question about Olive Branch law
Corpus searches the Olive Branch sections it holds and shows the ones that match, with their citations. Free, no sign-in.
