§ 31-146 — IGCC CHAPTER 8, INDOOR ENVIRONMENTAL QUALITY (IEQ) - amendments
Scottsdale Revised Code (Supp. No. 80: codified through Ordinance No. 4681, adopted July 1, 2025) · Scottsdale Revised Code § 31-146
Corpus is an independent public-information project, not the official City of Scottsdale website. Stable reference: corpuslaw.us/code/06dd57b2-71d5-47ed-acc5-548b49754abd
Sec. 31-146. - IGCC CHAPTER 8, INDOOR ENVIRONMENTAL QUALITY (IEQ) - amendments.
Only the following portions of CHAPTER 8, INDOOR ENVIRONMENTAL QUALITY (IEQ), are amended: (a) Section 801.3.1, Indoor air quality, is deleted in its entirety and amended to read as follows: 801.3.1 Indoor air quality. Buildings shall comply with the ventilation requirements of Chapter 4 of the City Mechanical Code (IMC). (b) Section 801.3.2, Thermal environmental conditions for human occupancy, is deleted in its entirety. (c) Section 801.3.3, Acoustical control, is amended to read as follows: 801.3.3 Acoustical control. Buildings shall comply with Section 1206, Sound Transmission and Section 1207, Enhanced Classroom Acoustics, of the City Building Code (IBC). (d) Section 801.3.4, Soil-gas control, is deleted. (e) Section 801.3.5, Lighting quality, is deleted. (f) Section 801.3.6, Moisture control, is deleted. (g) Section 801.3.7, Glare control, is deleted. (h) Section 801.3.8, Occupant override, is deleted. (i) Section 801.3.9, Exterior views, is deleted. (j) Section 801.4.1, Daylighting, is amended to read as follows: 801.4.1 Daylighting. Buildings shall comply with Section C402.4.2, Minimum skylight fenestration area, of the City Energy Code (IECC). (k) Section 801.4.2, Materials, including the exception is amended to read as follows: 801.4.2 Materials. Reported emissions or volatile organic compound (VOC) contents specified in the following subsections shall be from a representative product sample. Products certified under third-party certification programs as meeting the specific emission requirements listed in the following subsections shall be deemed to comply. (l) Section 801.4.2.1, Adhesives and sealants, is amended to read as follows, including adding a new table: 801.4.2.1 Adhesives and sealants. At least 85 percent by weight or volume, of specific categories of site-applied adhesives and sealants used on the interior side of building envelope, shall comply with the VOC content limits in Table 801.4.2.1 or alternative VOC emission limits in Table 801.4.2.1.1. TABLE 801.4.2.1 VOC CONTENT LIMITS FOR ADHESIVES AND SEALANTS ADHESIVES | VOC LIMIT grams per liter (g/L)a,b Building envelope membrane adhesive | 250 Carpet and carpet pad adhesives | 50 Ceramic tile adhesives | 65 Cove base adhesives | 50 Drywall and panel adhesives | 50 Multipurpose construction adhesives | 70 Rubber floor adhesive | 60 Structural glazing adhesives | 100 Subfloor Adhesive | 50 VCT and asphalt tile adhesives | 50 Wood flooring adhesives | 100 SEALANTS Architectural sealants including foam and grout | 250 a. Values in this table are derived from those specified by SCAQMD Rule 1168, October 2017. b. For low-solid adhesives and sealants, the VOC limit is expressed in grams per liter of material as specified in SCAQMD Rule 1168. For all other adhesives and sealants, the VOC limits are expressed in grams of VOC per liter of adhesive or sealant less water and less exempt compounds as specified in SCAQMD Rule 1168. Table 801.4.2.1.1 ADHESIVES AND SEALANTS VOC EMISSION LIMITS VOC | LIMIT Individual | ≤ ½ CA chronic REL a Formaldehyde | ≤ 16.5 µg/m 3 or ≤ 13.5 ppb b a. CDPH/EHLB/Standard Method V.1.1 Chronic Reference Exposure Level (CREL). b. Formaldehyde emission levels need not be reported for materials where formaldehyde is not added by the manufacturer of the material, (m) Section 801.4.2.2, Paints and coatings, is amended to read as follows, including adding a new table: 801.4.2.2 Paints and coatings. At least 85 percent by weight or volume, of site-applied interior architectural coatings shall comply with the VOC content limits in Table 801.4.2.2 or alternative VOC emission limits in Table 801.4.2.2.1. TABLE 801.4.2.2 VOC CONTENT LIMITS FOR PAINTS AND COATINGS CATEGORY | VOC LIMIT grams per liter (g/L)a,b Flat paints | 50 Nonflat paints | 50 Nonflat High-gloss paints | 150 Specialty coatings: Concrete/masonry sealers | 100 Floor coatings | 50 Primers, sealers and undercoats | 100 Stains | 250 Wood coatings | 275 a. Limits are expressed as VOC Regulatory, thinned to the manufacturer's maximum thinning recommendation, excluding any colorant added to tint bases. b. Values in this table are derived from those specified by the California Air Resources Board Suggested Control Measure for Architectural Coatings dated May 2020. Table 801.4.2.2.1 PAINTS AND COATINGS VOC EMISSION LIMITS VOC | LIMIT Individual | ≤ ½ CA chronic REL a Formaldehyde | ≤ 16.5 µg/m 3 or ≤ 13.5 ppb b a. CA Chronic Reference Exposure Level (CREL). b. Formaldehyde emission levels need not be reported for materials where formaldehyde is not added by the manufacturer of the material. (n) Section 801.4.2.3, Floor covering materials, is amended to read as follows, including adding a new table: 801.4.2.3 Floor covering materials. At least 85 percent of the total area of flooring installed within the interior of the building shall comply with the requirements in Table 801.4.2.3. Where flooring with more than one distinct product layer is installed, the emissions from each layer shall comply with these requirements. The test methodology used to determine compliance shall be from CDPH/EHLB/Standard Method V1.2 (commonly known as California Section 01350). The emissions testing shall be performed by a laboratory that has the CDPH/EHLB/ Standard Method V1.2 test methodology in the scope of its ISO 17025 Accreditation. Products certified under third-party certification programs as meeting the specific emission limits in Table 801.4.2.3 shall be an acceptable means for compliance. 801.4.2.3.1 Deemed to comply. 1. Floor covering products certified under nationally recognized third-party certification programs as meeting the emission requirements of Table 801.4.2.3. 2. Floor covering materials listed in Table 801.4.2.3.1, where post-manufacture coatings or surface applications have not been applied. Table 801.4.2.3 FLOOR COVERING VOC EMISSION LIMITS VOC | LIMIT Individual | ≤ ½ CA chronic REL a Formaldehyde | ≤ 16.5 µg/m 3 or ≤ 13.5 ppb a. CA Chronic Reference Exposure Level (CREL). TABLE 801.4.2.3.1 FLOOR COVERING MATERIALS DEEMED TO COMPLY WITH VOC EMISSION LIMITS Ceramic and concrete tile Natural stone Gypsum plaster Clay masonry Concrete masonry Concrete Metal (o) Section 801.4.2.5, Office furniture systems and seating, is deleted. (p) Section 801.4.2.6, Ceiling and wall assemblies and systems, is retitled and amended to read as follows, including adding a new table: 801.4.2.6 Acoustical ceiling tiles and wall systems. At least 85 percent of the total area of acoustical ceiling tiles and wall systems, shall comply with the requirements in Table 801.4.2.6. Where ceiling and wall systems with more than one distinct product layer are installed, the emissions from each layer shall comply with these requirements. The test methodology used to determine compliance shall be from CDPH/EHLB/Standard Method V1.2 (commonly known as California Section 01350). The emissions testing shall be performed by a laboratory that has the CDPH/EHLB/ Standard Method V1.2 test methodology in the scope of its ISO 17025 Accreditation. 801.4.2.6.1 Deemed to comply. 1. Ceiling and wall products certified under nationally recognized third-party certification programs as meeting the emission requirements of Table 801.4.2.6. 2. Ceiling and wall materials listed in Table 801.4.2.6.1 where post-manufacture coatings or surface applications have not been applied. TABLE 801.4.2.6 ACOUSTICAL CEILING AND WALL PRODUCTS VOC EMISSION LIMITS VOC | LIMIT Individual | ≤ ½ CA chronic REL a Formaldehyde | ≤ 16.5 µg/m 3 or ≤ 13.5 ppb a. CA Chronic Reference Exposure Level (CREL). TABLE 801.4.2.6.1 ACOUSTICAL CEILING AND WALL MATERIALS DEEMED TO COMPLY WITH VOC EMISSION LIMITS Ceramic and concrete tile Natural Stone Gypsum plaster Clay masonry Concrete masonry Concrete Metal (q) Section 801.4.2.7, Insulation, is deleted. (r) Section 801.4.3, Lighting for presentations, is deleted.
(Ord. No. 4576, § 1(Res. No. 12505, § 1(Exh. A)), 12-6-22, eff. 7-1-23)
Ask a question about Scottsdale law
Corpus searches the Scottsdale sections it holds and shows the ones that match, with their citations. Free, no sign-in.