Sec. 5.5-101. - Materials and colors.

(a) Materials should have good architectural character, be durable, and be selected for their compatibility with adjoining buildings and properties. Natural, traditional building materials are encouraged. Highly reflective and/or synthetic materials are prohibited. (b) Exterior materials should be selected based on their durability and appropriateness for their intended function. Special attention should be given to the durability of materials used around the ground floor of the building. Acceptable building materials include stone, brick, cement board, cementuous stucco and wood. The materials selected should require minimal maintenance. Their color should be integral to the material and not painted on (except in the case of wood). No more than three (3) painted or applied colors may be used on the exterior of any building. Colors of the predominate exterior surface material shall be subdued, with natural tones and neutral colors predominating. (c) Exterior insulating finishing (EFIS) and concrete masonry shall not be the predominant building material. EIFS should be used as a way to accentuate an architectural element and should be limited to areas not subject to damage or abuse (lower parts of buildings). Concrete masonry should be limited to split-face or burnished units. Painted, flat-faced concrete masonry units are prohibited. (d) Warehouse or manufacturing areas of industrial buildings may utilize metal veneer surface or precast concrete panels which are tinted or colored with the approval of the site and design committee. (e) Architectural consistency of colors, materials and detailing are to be provided between all building elevations. False or decorative facade treatments, where one (1) or more unrelated materials are placed upon the building are prohibited. Large parapet walls should reflect the function behind them and should not be freestanding. All elevations need not look alike; however, a sense of overall architectural continuity is strongly encouraged. (f) Inconsistent adornment and frequent changes in material shall be avoided. (g) All buildings shall be designed to be compatible with the most positive elements of community character as determined by the site and design review committee. (h) With the exception of industrial uses, the maximum unbroken facades plane shall be fifty (50) feet for multiple-family residential uses, and sixty (60) feet for commercial and office uses. The wall of any such building shall be interrupted through the use of projections or recesses, portals, courtyards, plazas or other appropriate architectural conventions. The design of off-setting wall plane projections or recesses shall have a minimum depth of two (2) feet. (i) No flat-faced cement block or metal surfaces shall be visible upon the exterior of any building. (j) Where pitched roofs are utilized, the primary roof form shall be on a slope of no less than six-twelfths. Porches shall be on a slope of not less than three-twelfths. Pitched roofs shall be shingled with wood textured composition shingles or architectural shingles. Roof design should be appropriate for the architectural style of the building. Enameled standing seam metal, flat tiles of concrete or clay, and copper metal roofs are permitted. All surfaces are permitted when the roof is concealed from public view by parapets (flat, built up or pitched roofs). The use of plastic, fiberglass, other metal, or glass, visible to public view, is strictly prohibited. The use of bright, high intensity colors is strictly prohibited. (k) The treatment of doors and windows shall be uniform throughout the building design, with the exception of designated fire doors located on the rear of the building. (l) Parapet facades may be used when of unified construction with the primary surface of the wall and of the same material and color. The parapet shall be designed such that the reverse side of all elements shall not be visible to public view. False mansards are prohibited. Canopies are permissible provided they are an integrated part of the overall building design, are not used to create the impression of a false mansard, and are not used as a location or support for wall-mounted signage (painted signs on canopies are permitted).

(Ord. No. 2010-02-735, 2-16-10; Ord. No. 2012-01-769, 1-3-12; Ord. No. 2020-09-881, § 2, 9-15-20)

Ask a question about Batesville law

Corpus searches the Batesville sections it holds and shows the ones that match, with their citations. Free, no sign-in.