§ 15.03.040 — AMENDMENTS TO THE CALIFORNIA RESIDENTIAL CODE

Anaheim Municipal Code (2026 S-28: local legislation current through Ord. 6627, passed 8-11-2026) · Anaheim Municipal Code § 15.03.040

Corpus is an independent public-information project, not the official City of Anaheim website. Stable reference: corpuslaw.us/code/07f89dfa-3394-453e-a00b-30f0e46eecca

15.03.040 AMENDMENTS TO THE CALIFORNIA RESIDENTIAL CODE.

The 2025 Edition of the California Residential Code is amended as set forth in this section: .010 The Anaheim Residential Code is hereby amended, modified and supplemented by the addition and application of the provisions of Section 15.03.040 of this Code. .020 Subsection R105.2 of Section R105 of Division II of Chapter 1 is revised by amending item 1 as follows: 1. Other than storm shelters, one-story detached accessory structures used as storage sheds, playhouses, gazebo, and similar uses, provided that the floor area does not exceed 120 square feet (11.15m²), the structure is not more than 10 (ten) feet in height above grade, the structure is not provided with electrical, plumbing, and/or mechanical installations, and not used as carports or habitable rooms, with a minimum 5 (five) foot separation from any other structure. .030 Table R301.2 of Chapter 3 is revised to read in full as follows: TABLE R301.2 - CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA Ground Snow Loado | Wind Design | Seismic Design Categoryf | Subject To Damage From | Ice Barrier Underlayment Requiredh | Flood Hazardsg | Air Freezing Indexi | Mean Annual Temp j Speedd (mph) | Topographic effectsk | Special wind regionl | Windborne debris zonem | Weatheringa | Frost line depth b | Termitec Zero | 95 | No | No | No | D2 or E | Negligible | 12-14" | Very Heavy | No | Y/N | Zero | 60 MANUAL J DESIGN CRITERIAn Elevation | Altitude correction factore | Coincident wet bulb | Indoor winter design relative humidity | Indoor design dry-bulb temperature | Outdoor winter design dry-bulb temperature | Heating Temperature Difference (-10) - 1755 | 1.00-95 | 69 | 75 | — | 39 | — Latitude | Daily range | Summer design gains | Indoor summer design relative humidity | Indoor summer design dry-bulb temperature | Outdoor summer design dry-bulb temperature | Cooling Temperature Difference 34 | 26 | — | 15(50% RH) | — | 89 | — For SI: 1 pound per square foot = 0.0479 kPa, 1 mile per hour = 0.447 m/s. a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code, the frost line depth strength required for weathering shall govern. The weathering column shall be filled in with the weathering Index, "negligible," "moderate" or "severe" for concrete as determined from Figure R301.2(1). The grade of masonry units shall be determined from ASTM C34, ASTM C55, ASTM C62, ASTM C73, ASTM C90, ASTM C129, ASTM C145, ASTM C216 or ASTM C652. b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1), the frost line depth strength required for weathering shall govern. The jurisdiction shall fill in the frost line depth column with the minimum depth of footing below finish grade. c. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. d. The jurisdiction shall fill in this part of the table with the wind speed from the ultimate design wind speeds map [Figure R301.2(2)]. Wind exposure category shall be determined on a site- specific basis in accordance with Section R301.2.1.4. e. The jurisdiction shall fill in this section of the table to establish the design criteria using Table 10A from ACCA Manual J or established criteria determined by the jurisdiction. f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. g. The jurisdiction shall fill in this part of the table with: the date of the jurisdiction's entry into the National Flood Insurance Program (date of adoption of the first code or ordinance for management of flood hazard areas); and the title and date of the currently effective Flood Insurance Study or other flood hazard study and maps adopted by the authority having jurisdiction, as amended. h. In accordance with Sections R905.1.2, R905.4.3.1, R905.5.3.1, R905.6.3.1, R905.7.3.1 and R905.8.3.1, where there has been a history of local damage from the effects of ice damming, the jurisdiction shall fill in this part at the table with "YES." Otherwise, the jurisdiction shall fill in this part of the table with "NO." i. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index (BF-days) from Figure R403.3(2) or from the 100-year (99 percent) value on the National Climatic Data Center data table "Air Freezing Index-USA Method (Base 32°F)." j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table "Air Freezing Index-USA Method (Base 32°F)." k. In accordance with Section R301.2.1.5, where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects, the jurisdiction shall fill in this part of the table with "YES." Otherwise, the jurisdiction shall indicate "NO" in this part of the table. l. In accordance with Figure R301.2(2), where there is local historical data documenting unusual wind conditions, the jurisdiction shall fill in this part of the table with "YES" and identify any specific requirements, Otherwise, the jurisdiction shall indicate "NO" in this part of the table. m. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s). Otherwise, the jurisdiction shall indicate "NO" in this part of the table. n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1a or 1b from ACCA Manual J or established criteria determined by the jurisdiction. o. The jurisdiction shall fill in this section of the allowable stress design table using the Ground Snow Loads in Figure R301.2(3). .40 Subsection R902.1 of Section R902 of Chapter 9 is revised to allow only class A or B roofs as follows: R902.1 Roofing covering materials. Roofs shall be covered with materials as set forth in Sections R904 and R905. A minimum of Class A or B roofing shall be installed in areas designated by this section. Classes A or B roofing required by this section to be listed shall be tested in accordance with UL 790 or ASTM E 108. Where required, the roof assembly shall be listed and identified as to Class by an approved testing agency. Exceptions: 1. Class A roof assemblies include those with coverings of brick, masonry and exposed concrete roof deck. 2. Class A roof assemblies also include ferrous or copper shingles or sheets, metal sheets and shingles, clay or concrete roof tile, or slate installed on noncombustible decks. .050 Paragraph R902.1.2 of Subsection R902.1 of Section R902 of Chapter 9 is revised it to require a minimum Class B roof as follows: R902.1.2 Roof coverings within all other areas. The entire roof covering of every existing structure where more than 50 percent of the total roof area is replaced within any one-year period, the entire roof covering of every new structure, and any roof covering applied in the alteration, repair or replacement of the roof of every existing structure, shall be a fire-retardant roof covering that is at least Class B fire classification. .060 The first paragraph of Subsection R902.2 of Section R902 of Chapter 9 is revised to allow only Class A or B treated wood roofs as follows: R902.2 Fire-retardant-treated shingles and shakes. Fire-retardant-treated wood shakes and shingles are wood shakes and shingles complying with UBC Standard 15-3 or 15-4 which are impregnated by the full-cell vacuum-pressure process with fire-retardant chemicals, and which have been qualified by UBC Standard 15-2 or ASTM E108 or UL790 for use on Class A or B roofs. .070 Subsection 115922(a) of Section CI100 of Appendix CI is hereby amended as follows: Except as provided in Section 115925, when a building permit is issued for the construction of a new swimming pool or spa or the remodeling of an existing swimming pool or spa at a private single-family home, the respective swimming pool or spa shall be equipped with item #1 below AND at least one additional following seven drowning prevention features. .080 Subsection CI100 (115922) of Appendix CI is amended as follows: 1. A non-removable enclosure that meets the requirements of 115923 and isolates the swimming pool and spa from the private single-family home. Any walls of the residential structure or accessory structures used to complete the isolation enclosure must have door openings equipped with protection as required in 115922 #4 or #5. Any such door protection device provided for this purpose may not be used to comply with the second drowning prevention feature requirement. (Ord. 6613 § 2 (part); September 23, 2025.)

Ask a question about Anaheim law

Corpus searches the Anaheim sections it holds and shows the ones that match, with their citations. Free, no sign-in.