§ 10-301 — Green building requirements for new buildings
Denver Revised Municipal Code (Supp. No. 147, Update 3: codified through Ordinance No. 0852-26, enacted July 13, 2026) · Denver Revised Municipal Code § 10-301
Corpus is an independent public-information project, not the official City of Denver website. Stable reference: corpuslaw.us/code/07fbe8cf-eba4-40cc-8f4c-216161d42e3e
Sec. 10-301. - Green building requirements for new buildings.
(a) In general. Except as provided in subsection 10-301(c) below, an owner constructing a building containing twenty-five thousand (25,000) square feet or greater of gross floor area who has not submitted a formal site development plan application with payment of all applicable fees by 4:30 pm on November 2, 2018 must provide the following green building requirements: (1) A cool roof; and (2) One (1) of the following options: a. Green space covering an area in one (1) of the following amounts, whichever is least: 1. Ten (10) percent of the gross floor area of the building; 2. Sixty (60) percent of the total roof area on the building. b. On-site solar panels covering an area anywhere on the building or zone lot equal to seventy (70) percent of the total roof area or an area equal to an amount required to provide one hundred (100) percent of estimated annual average electricity used at the building. Other renewable energy devices may be used in place of on-site solar panels so long as the owner provides evidence of similar generation capacity. Any net zero energy building complies with this subsection 10-301(a)(2)b. c. Off-site renewable energy purchase with the following requirements: 1. The off-site renewable energy purchase must be met through a minimum five (5) year contract for a subscription, lease, or purchase of a share in a voluntary renewable energy program offered by Xcel Energy or a community solar project for which a dedicated renewable energy resource located in Public Service Company of Colorado territory is built for that customer program, and which has dedicated customer capacity or energy to fulfill that customer's subscription; 2. The term of purchase must be renewed a minimum of every five (5) years for the life of the building; and 3. The off-site renewable energy purchase must cover the equivalent energy production of either (i) the estimated one hundred (100) percent of electricity the building will use, or (ii) the amount that would have been provided with required on-site solar panels and demonstration of decreased energy consumption measured as estimated energy savings of a minimum six (6) percent above requirements in the applicable Denver Building Code and Denver Fire Code as measured according to the selected Denver Energy Code performance based compliance path. d. A combination of construction of an all-electric property and demonstration of decreased energy consumption measured as estimated cost savings of at least twelve (12) percent above requirements in the applicable Denver Building Code and Denver Fire Code as measured according to the selected Denver Energy Code performance based compliance path. e. Building certification of LEED Gold, Enterprise Green Communities, the National Green Building Standard ICC/ASHRAE 700 Gold, Green Globes New Construction Four Globes rating, International Living Future Institute Living Building Challenge certification, International Living Future Institute Core Green Building certification, International Living Future Institute Zero Energy certification, International Living Future Institute Zero Carbon certification, Denver Green Code Enhanced Use Program compliance verification, or an equivalent certification approved by the building official. f. A combination of green space, and renewable energy device(s) with the following required coverages: 1. Green space covering an area in one (1) of the following amounts, whichever is least: (i) Three (3) percent of the gross floor area of the building; or (ii) Eighteen (18) percent of the total roof area on the building and either section 10-301(a)(2)f.2 or 3 below. 2. On-site solar panels located anywhere on the subject zone lot covering an area in one of the following amounts, whichever is least: (i) Seven (7) percent of the gross floor area of the building; or (ii) Forty-two (42) percent of the total roof area on the building. 3. Renewable energy devices, other than solar panels, so long as the renewable energy devices achieve equivalent total energy production to the required amount of on-site solar panels in subsection 10-302(2)f.2 above; or 4. Alternative coverages of green space and on-site solar panels may be approved by the building official so long as the combination covers an area in one (1) of the following amounts, whichever is least: (i) Ten (10) percent of the gross floor area of the building; or (ii) Sixty (60) percent of total roof area on the building. g. A combination of green space and off-site renewable energy purchase, with the following requirements: 1. Green space covering an area in one (1) of the following amounts, whichever is least: (i) Three (3) percent of the gross floor area of the building; or (ii) Eighteen (18) percent, of total roof area on the building. 2. The off-site renewable energy purchase must be met through a minimum five (5) year contract for a subscription, lease, or purchase of a share in a voluntary renewable energy program offered by Xcel Energy or a community solar project for which a dedicated renewable energy resource located in Public Service Company of Colorado territory is built for that customer program, and which has dedicated customer capacity or energy to fulfill that customer's subscription. The term of purchase must be renewed a minimum of every five (5) years after initial purchase. 3. The off-site renewable energy purchase must cover the amount that required on-site solar panels would have provided and demonstration of decreased energy consumption measured as estimated energy savings of a minimum two and one-half (2.5) percent above requirements in the Denver Building Code and Denver Fire Code as measured according to the selected Denver Energy Code performance based compliance path. h. A combination of green space and decreased energy consumption with the following requirements: 1. Green space covering an area in one (1) of the following amounts, whichever is least: (i) Three (3) percent of the gross floor area of the building; or (ii) Eighteen (18) percent of total roof area on the building. 2. A combination of construction of an all-electric property and demonstration of decreased energy consumption measured as estimated energy savings of a minimum five (5) percent above requirements in the applicable Denver Building Code and Denver Fire Code as measured according to the selected Denver Energy Code performance based compliance path. (b) Payment into the green building fund. (1) Instead of providing required green space, an owner may pay an amount to the green building fund, defined in division 3 below, of fifty dollars ($50.00) per square foot of all green space coverage required in subsections 10-301(a)(2)a, f, g, or h, but not provided. (2) In cases where an owner chooses to provide green space as required in subsections 10-301(a)(2)a, f, g, or h, but is unable to provide the entirety required green space coverage, the owner may pay fifty dollar ($50.00) per square foot for no more than twenty-five (25) percent of the green space required, but not provided, and must provide at least seventy-five (75) percent of the required green space coverage. (3) In cases where an owner chooses to provide on-site solar panels as required in subsections 10-301(a)(2)b or f, but is unable to provide the entirety required on-site solar panel coverage, the owner may pay fifty dollar ($50.00) per square foot for no more than twenty-five (25) percent of the on-site solar panel coverage required, but not provided, and must provide at least seventy-five (75) percent of the required on-site solar panel coverage. (c) Exceptions. (1) Subsection 10-301(a) shall not apply to the following: a. One- and two-family dwellings constructed under the provisions of the International Residential Code; b. Dwelling units constructed in a group of three (3) or more attached units in which each unit extends from foundation to roof and is not more than three (3) stories above grade plane; or c. Temporary structures, air supported structures, and greenhouses. (2) Subsection 10-301(a)(1) shall not apply to the following: a. Portions of a proposed roof that include the following: 1. Photovoltaic systems or components; 2. Solar-, air-, or water-heating systems or components; 3. Vegetated roofs; 4. Above-roof decks or walkways; or 5. HVAC systems and components, and other opaque objects mounted above the roof. b. Portions of a proposed roof shaded during the peak sun angle on the summer solstice by neighboring buildings or other portions of the same building; c. Portions of a proposed roof that are ballasted with a minimum stone ballast of fifteen (15) pounds per square foot; d. Twenty-five (25) percent of an individual roof section, when the remaining seventy-five (75) percent of the proposed individual roof section contains a cool roof; e. An individual roof section containing less than twenty five (25) percent of roofing materials; or f. Visible roofs for no more than ten (10) percent of the total roof area. (3) Subsection 10-301(a)(2) shall not apply to residential buildings five (5) stories or fewer, less than sixty-two and one-half (62.5) feet in height, and with twenty-five thousand (25,000) square feet or more of gross floor area. (d) Character defining roof. When a proposed roof is determined to be a character defining roof, the building official may allow roof materials that do not meet the requirements for a cool roof. (e) Continuing compliance. An owner of a building subject to the requirements of section 10-301(a) must provide a cool roof and one (1) of the options of 10-301(a)(2) for the duration of the building's existence.
(Ord. No. 1134-18, § 1, 10-29-18; Ord. No. 1653-22, § 3, 1-9-23; Ord. No. 543-23, § 2, 6-5-23)
Ask a question about Denver law
Corpus searches the Denver sections it holds and shows the ones that match, with their citations. Free, no sign-in.