§ 535.1470 — Floodway District

Minneapolis Code of Ordinances (Supp. No. 73, Update 1: codified through Ordinance No. 2026-020, adopted June 25, 2026) · Minneapolis Code of Ordinances § 535.1470

Corpus is an independent public-information project, not the official City of Minneapolis website. Stable reference: corpuslaw.us/code/080b8f67-6fe5-4ae9-b4aa-8974c55cf84c

535.1470. - Floodway District.

(a) Permitted uses in the Floodway District. The following uses, subject to the standards set forth in section 535.1470(b), are permitted uses if otherwise allowed in the underlying zoning district or any applicable overlay district: (1) Outdoor plant nurseries. (2) Parking and loading areas. (3) Open space uses, including but not limited to private and public golf courses, tennis courts, driving ranges, archery ranges, picnic grounds, boat launching ramps, swimming areas, parks, wildlife and nature preserves, game farms, fish hatcheries, shooting preserves, hunting and fishing areas, and single or multiple purpose recreational trails. (4) Residential lawns, gardens, parking areas, and play areas. (5) Railroads, streets, bridges, utility transmission lines and pipelines, provided that the Department of Natural Resources' Area Hydrologist is notified at least ten (10) days prior to issuance of any permit. (b) Standards for permitted uses in the Floodway District. (1) The use must have low flood damage potential. (2) The use must not obstruct flood flows or cause any increase in flood elevations and must not involve structures, obstructions, or storage of materials or equipment. (3) Any facility that will be used by employees or the general public must be designed with a flood warning system that provides adequate time for evacuation if the area is inundated to a depth and velocity such that the depth (in feet) multiplied by the velocity (in feet per second) would exceed a product of four (4) upon occurrence of the regional one (1) percent chance flood. (c) Conditional uses in the Floodway District. The following uses may be allowed as conditional uses following the standards and procedures set forth in section 535.1450 of this ordinance and further subject to the standards set forth in section 535.1470(d) if otherwise allowed in the underlying zoning district or any applicable overlay district. (1) Structures accessory to a permitted or conditional use. (2) Storage of sand, gravel, and other materials. (3) Marinas, boat rentals, docks, piers, wharves, and water control structures. (4) Storage yards for equipment, machinery, or materials. (5) Placement of fill or construction of fences that obstruct flood flows. (6) Travel-ready recreational vehicles meeting the exception standards in section 535.1510(b). (d) Standards for floodway conditional uses. (1) A conditional use shall not cause any increase in the stage of the one (1) percent chance or regional flood or cause an increase in flood damages in the reach or reaches affected. (2) Fill; storage of materials and equipment. a. The storage or processing of materials that are, in time of flooding, flammable, explosive, or potentially injurious to human, animal, or plant life is prohibited. b. Fill, dredge spoil, and other similar materials deposited or stored in the floodplain must be protected from erosion by vegetative cover, mulching, riprap or other acceptable method. Permanent sand and gravel operations and similar uses must be covered by a long-term site development plan. c. Temporary placement of fill, other materials, or equipment which would cause an increase to the stage of the one (1) percent chance or regional flood may only be allowed if the planning commission has approved a plan that assures removal of the materials from the floodway based upon the flood warning time available. (3) Accessory structures, as identified in section 535.1470(c)(1), may be permitted, provided that: a. Structures are not intended for human habitation; b. Structures will have a low flood damage potential; c. Structures will be constructed and placed so as to offer a minimal obstruction to the flow of flood waters; d. Service utilities, such as electrical and heating equipment, within these structures must be elevated to or above the regulatory flood protection elevation or properly floodproofed; and e. Structures must be elevated on fill or structurally dry floodproofed in accordance with the FP1 or FP2 floodproofing classifications in the state building code. All floodproofed structures must be adequately anchored to prevent flotation, collapse or lateral movement and designed to equalize hydrostatic flood forces on exterior walls. f. As an alternative, an accessory structure may be internally/wet floodproofed to the FP3 or FP4 floodproofing classifications in the state building code, provided the accessory structure constitutes a minimal investment and does not exceed five hundred seventy-six (576) square feet in size. Designs for meeting this requirement must either be certified by a registered professional engineer or meet or exceed the following criteria: 1. To allow for the equalization of hydrostatic pressure, there must be a minimum of two (2) "automatic" openings in the outside walls of the structure, with a total net area of not less than one (1) square inch for every square foot of enclosed area subject to flooding; and 2. There must be openings on at least two (2) sides of the structure and the bottom of all openings must be no higher than one (1) foot above the lowest adjacent grade to the structure. Using human intervention to open a garage door prior to flooding will not satisfy this requirement for automatic openings. (4) Structural works for flood control that will change the course, current or cross section of protected wetlands or public waters are subject to the provisions of Minn. Statutes, Section 103G.245. (5) A levee, dike or floodwall constructed in the floodway must not cause an increase to the one (1) percent chance or regional flood. The technical analysis must assume equal conveyance or storage loss on both sides of a stream. (6) Floodway developments must not adversely affect the hydraulic capacity of the channel and adjoining floodplain of any tributary watercourse or drainage system. (7) Within an AO Zone, there must be adequate drainage paths around structures on slopes to guide floodwaters around and away from proposed structures or structure additions.

Ask a question about Minneapolis law

Corpus searches the Minneapolis sections it holds and shows the ones that match, with their citations. Free, no sign-in.