Sec. 8-401. - Definitions.
The following definitions and terms shall apply in the interpretation and enforcement of this chapter: (1) Air-gap: A physical separation between a water supply and the overflow rim of a non-pressurized vessel or drain. An "approved air gap" shall be a distance at least twice the diameter of the supply pipe, but no less than two (2) inches. (2) Atmospheric vacuum breaker: A device which prevents back-siphonage by creating an atmospheric vent when there is either a negative pressure or sub-atmospheric pressure in the water system. (3) Auxiliary intake: Any water supply, on or available to a premises, other than that directly supplied by the public water supply. This may include water from another public water system, any natural source, such as a well, spring, river, and so forth; used, reclaimed or recycled waters; or industrial fluids. (4) Bypass: Any system of piping or other arrangement whereby water may be diverted around the treatment plant or protection devices. (5) Backflow: The reversal of the intended direction of flow of water or mixtures of water and other liquids, gases or substances into the distribution pipes of a potable water system. (6) Back pressure: A pressure higher than the supply pressure caused by a pump, elevated tank, steam or air pressure. (7) Back-siphonage: Backflow caused by negative or reduced pressure in the supply piping. (8) Cross-connection: Any physical or potential connection whereby the public water supply is connected with any other water system, whether private or public, either inside or outside any building or buildings, in such a manner that flow of water into the public water supply is possible through the manipulation of valves or because of ineffective check of back pressure valves, or because of any other arrangement. (9) General manager: The manager of the Clarksville public water supply, or his authorized deputy, agent, or representative. (10) Interconnection: Any system of piping or other arrangement whereby the public water system is connected directly with a sewer, drain, conduit, pool, storage reservoir, or other device which does or may contain sewage or other waste liquid which would be capable of imparting contamination to the public water supply. (11) Person: Any and all persons, natural or artificial, including any individual, firm, or association, and any municipal or private corporation organized or existing under the laws of this or any other state or country. (12) Pressure vacuum breaker: An assembly consisting of a device containing one or two (2) independently operating spring loaded check valves and an independently operating spring loaded air inlet valve located on the discharge side of the check valves, with tightly closing shut-off valves on each side of the check valves and properly located test cocks for the testing of the check valves and relief valves. (13) Public water supply: The waterworks system furnishing water to the City of Clarksville, Tennessee, for general use and which supply is recognized as the public water supply by the Tennessee Department of Environment and Conservation, Division of Water Supply. (14) Reduced pressure backflow prevention device: An assembly consisting of two (2) independently operating approved check valves with an automatically operating differential relief valve located between the two (2) check valves, tightly closing resilient seated shut-off valves, plus properly located resilient seated test cocks for the testing of the check valves and the relief valve.
(Ord. No. 30-1998-99, 1-7-99)
Ask a question about Clarksville law
Corpus searches the Clarksville sections it holds and shows the ones that match, with their citations. Free, no sign-in.