§ 565-502 — General standards
Revised Code of the Consolidated City and County of Indianapolis-Marion County (Supp. No. 47, Update 2: codified through Ordinance No. 42, 2026, passed June 1, 2026) · Indianapolis-Marion County Revised Code § 565-502
Corpus is an independent public-information project, not the official City of Indianapolis website. Stable reference: corpuslaw.us/code/0825d5ba-71e3-4503-89e1-ab7bb40f37f9
Sec. 565-502. - General standards.
In all areas of special flood hazard, the following provisions are required: (a) All new construction, reconstruction or repairs made to a repetitive loss structure, and substantial improvements shall be anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy. (b) New construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage below the FPG. (c) New construction and substantial improvements must incorporate methods and practices that minimize flood damage. (d) Electrical, heating, ventilation, plumbing, air conditioning equipment, and other service facilities shall be located at/above the FPG for residential structures. Electrical, heating, ventilation, plumbing, air conditioning equipment, and other service facilities shall be located at/above the FPG or designed so as to prevent water from entering or accumulating within the components below the FPG for non-residential structures. Water and sewer pipes, electrical and telephone lines, submersible pumps, and other waterproofed service facilities may be located below the FPG. (e) New and replacement water supply systems shall be designed to minimize or eliminate infiltration of floodwaters into the system. (f) New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of floodwaters into the system. (g) On-site waste disposal systems shall be located and constructed to avoid impairment to them or contamination from them during flooding. (h) Any alteration, repair, reconstruction, or improvements to a structure that is in compliance with the provisions of this chapter shall meet the requirements of "new construction" as contained in this chapter. (i) Base flood elevation data shall be provided for subdivision proposals and other proposed development (including manufactured home parks and subdivisions), that is greater than fifty (50) lots or five (5) acres, whichever is less. (j) Where an existing or proposed structure or other development is affected by multiple flood zones, by multiple base flood elevations, or both, the development activity must comply with the provisions of this chapter applicable to the most restrictive flood zone and the highest base flood elevation affecting any part of the existing or proposed structure; or for other developments, affecting any part of the area of the development. The development will be designed with the lowest floor elevation including any basement provided and maintained at or above flood protection grade of at least two (2) feet above the base flood elevation. (k) Drainage paths must be provided to guide floodwaters around and away from proposed structures to be constructed on slopes in areas of shallow flooding, designated as zone AO or Zone AH on the FIRM. (l) Fill projects that do not involve a structure must be protected against erosion and scour during flooding by vegetative cover, riprap, or bulk heading. If vegetative cover is used, the slopes shall be no steeper than three (3) feet horizontal to one (1) foot vertical. (m) Non-conversion agreements shall be required for all new or substantially improved elevated structures with an enclosure beneath the elevated floor, accessory structures, and open-sided shelters. (n) Construction of new solid waste disposal facilities, hazard waste management facilities, salvage yards, and chemical storage facilities shall not be permitted in areas of special flood hazard. (o) Floodplain performance surety. The following standards shall apply to all floodplain performance surety. (1) The surety must be either a performance bond or letter of credit on the approved department of business and neighborhood services forms. (2) The amount of the surety must equal one percent of the total cost of all proposed improvements but in no case be less than two thousand dollars ($2,000.00) per building on the site. (3) The surety must be valid, without expiration, until released by the floodplain administrator and/or designee. (4) To obtain the release of the floodplain performance surety, the floodplain administrator and/or designee shall determine if the required certificates are completed accurately and without errors. (5) The floodplain administrator may utilize the floodplain performance surety to obtain the required certificate should the applicant fail to provide one. (p) General regulations applicable to all special flood hazard areas. The following regulations shall apply to all land within any special flood hazard area: (1) From and after October 4, 1971: a. No land, watercourse, building, structure, premises or part thereof shall be used or occupied except in conformity with these regulations and for uses permitted by this article. b. No land, watercourse, building, structure, premises, use or part thereof shall be constructed, erected, converted, enlarged, extended, reconstructed, relocated, altered, improved, or repaired except in conformity with these regulations and for uses permitted by the flood damage prevention ordinance. (2) No land alteration, watercourse alteration, open land use, legally established nonconforming use, or structure as defined in this article shall be constructed, erected, placed, converted, enlarged, extended, reconstructed, improved, repaired, restored, or relocated until a floodplain development permit is issued for the proposed activity as required by the flood damage prevention ordinance. (q) Fencing must be designed to minimize the obstruction of floodwaters by such measures as providing flow-through rather than solid fencing, reduction of structure cross-section are perpendicular to the flow path, and placement of nonbuilding structures away from the area of greater depth or velocities.
(G.O. 22, 2024, § 1)
Ask a question about Indianapolis law
Corpus searches the Indianapolis sections it holds and shows the ones that match, with their citations. Free, no sign-in.
