§ 145.3803 — Local Modifications and Additions to Section Q106 “Tents and Membrane Structures” of the California Building Code
San Diego Municipal Code (City Clerk PDFs, pages revised through October 2026) · San Diego Municipal Code § 145.3803
Corpus is an independent public-information project, not the official City of San Diego website. Stable reference: corpuslaw.us/code/085c1b0e-4789-479f-af9d-4f9088e94a42
§ 145.3803 Local Modifications and Additions to Section Q106 “Tents and Membrane Structures” of the California Building Code
(a) Section Q106 is adopted with modifications and additions under Sections 145.0105 and 145.0106 of the Land Development Code. (b) Section Q106.1 General is added as follows: (1) Section Q106.1.1 Tents is modified as follows: Q106.1.1 Tents. Tents shall not be used to house occupants for more than 7 consecutive days unless such tents are maintained with tight wooden floors raised at least 4 inches (101.6 mm) above the ground level and are equipped with baseboards on all sides to a height of at least 6 inches (152.4 mm). Tents may be maintained with concrete slabs with the finished surface at least 4 inches (101.6 mm) above grade and equipped with curbs on all sides at least 6 inches (152.4 mm) high. A tent shall not be considered a suitable sleeping place when it is found necessary to provide heating facilities in order to maintain a minimum temperature of 50 degrees Fahrenheit (10 degrees Celsius) within such tent during the period of occupancy. (2) Section Q106.1.2 Membrane Structures is added with modification as follows: Q106.1.2 Membrane Structures. Membrane structures installed and/or assembled in accordance with Chapter 31 of the California Building Code and the California Fire Code may be permitted to be used as emergency housing and emergency housing facilities. (c) Section Q106.2 Membrane Structures In Use for More than 180 Days is added as follows: Q106.2 Membrane Structures In Use for More Than 180 Days. Membrane structures in use for a period of more than 180 calendar days shall comply with the California Fire Code and with the following: (1) The membrane structure shall be inspected by a California registered design professional at least once every 180 calendar days from the date of final inspection to ensure that the membrane structure continues to perform as designed and initially erected. The registered design professional shall certify in writing that the membrane structure continues to be in compliance with the applicable regulations of the California Fire Code and California Building Code in effect on the date of final inspection. Inspection records shall be kept and shall be made available for verification by the Fire Code Official and the Building Official. (2) The Fire Code Official shall inspect the membrane structure prior to initial occupancy and at least once every 90 days thereafter to verify compliance with the approved operations plan and the conditions of approval in effect at the time of final inspection and prior to initial occupancy. (d) Section Q106.3 Means of Egress is added as follows: Q106.3 Means of Egress. Means of egress for membrane structures used as emergency housing shall be determined based on the occupant load specified in Section P103.3. (e) Section Q106.4 Storage of Flammable Materials Within Tents or Membrane Structures is added as follows: Q106.4 Storage of Flammable Materials Within Tents or Membrane Structures. Flammable materials, including the possessions of occupants and users stored in tents and membrane structures shall not obstruct required aisle widths between beds or other furnishings. The quantity of stored flammable materials within a membrane structure not protected with an automatic fire sprinkler system, or within tents, shall be subject to the approval of the Fire Code Official. (f) Section Q106.5 Flammable or Combustible Liquids is added as follows: Q106.5 Flammable or Combustible Liquids. The possession or storage of any flammable or combustible liquids or gases shall not be permitted inside a tent or membrane structure except for intact cigarette lighters. The use of any type of open flame inside a tent or membrane structure is prohibited unless each separate use is approved by the Fire Code Official. (g) Section Q106.6 Fire Department Access is added as follows: Q106.6 Fire Department Access. Fire Department access to tents or membrane structures used for emergency housing shall be in compliance with Section 503, Section 504, and Appendix D of the California Fire Code as adopted with modifications in Section 511.8201(f) of the San Diego Municipal Code and approved by the Fire Code Official. (h) Section Q106.7 Water Supply is added as follows: Q106.7 Water Supply. An approved fire protection water supply complying with Section 507 of the California Fire Code, or as approved by the Fire Code Official, shall be provided for each tent or membrane structure, group of structures, or premises used for emergency housing.
(“Local Modifications and Additions to Section N106 ‘Tents and Membrane Structures’ of the California Building Code” added 3-19-2019 by Emergency Ordinance O-21060 N.S.; effective 3-19-2019.) (“Local Modifications and Additions to Section N106 ‘Tents and Membrane Structures’ of the California Building Code” added 4-15-2019 by O-21064 N.S.; effective 5-15-2019.) (Retitled to “Local Modifications and Additions to Section O106 ‘Tents and Membrane Structures’ of the California Building Code” and amended 4-9-2020 by O-21181 N.S.; effective 5-9-2020.) (Retitled to “Local Modifications and Additions to Section P106 “Tents and Membrane Structures” of the California Building Code” and amended 5-8-2023 by O-21642 N.S.; effective 6-7-2023.) (Retitled to “Local Modifications and Additions to Section Q106 “Tents and Membrane Structures” of the California Building Code” and amended 3-23-2026 by O-22080 N.S.; effective 4-22-2026.) Editors Note: Amendments as adopted by O-22109 N.S. will not apply within the Coastal Overlay Zone until the California Coastal Commission certifies it as a Local Coastal Program Amendment. Click the link to view the Strikeout Ordinance highlighting changes to prior language http://docs.sandiego.gov/municode_strikeout_ord/O-22109-SO.pdf ]
Ask a question about San Diego law
Corpus searches the San Diego sections it holds and shows the ones that match, with their citations. Free, no sign-in.