For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 7-194.1 — General requirements

Code of Ordinances of the City of Greenville, Mississippi (Supp. No. 31: codified through Ordinance No. 24-007, enacted August 26, 2024) · Greenville Code of Ordinances § 7-194.1

Corpus is an independent public-information project, not the official City of Greenville website. Stable reference: corpuslaw.us/code/08a1f8d7-b275-4c64-a291-60149aad0598

Sec. 7-194.1. - General requirements.

(a) All existing FSEs are required to have GCEs installed, maintained, and operating properly, in accordance with the Sewer Use Ordinance (Attachment L). (b) All FSEs will be required to maintain records of cleaning and maintenance of GCE. GCE maintenance records include, at a minimum, the date of cleaning/maintenance, company or person conducting the cleaning/maintenance, volume (in gallons) of grease wastewater removed, and final disposal location. A completed Grease Waste Hauler Manifest (Attachment A), that includes all the minimum information mentioned above, will meet this requirement. (c) GCE maintenance records will be available at the FSE premises so they can be furnished to the city or their representative, and/or the health department. The FSE shall maintain GCE maintenance and manifest records for three (3) years. (d) No FSE will discharge oil and grease in concentrations that exceed the city numerical limit for oil and grease of 100 mg/L. (e) Owners of commercial property will be held responsible for wastewater discharges from the leaseholder on their property. (f) All establishments with GCE must have their grease interceptor or grease trap inspected and certified annually by a city licensed plumber. If a grease interceptor or grease trap "passes" the annual certification requirement, then no further action is required. If a grease interceptor or grease trap "fails" the certification requirement, then a corrective action response is required from the FSE owner or authorized representative to the city. An Annual Grease Interceptor Certification and Construction Inspection Form (Attachment B) or Annual Grease Trap Certification and Construction Inspection Form (Attachment C) must be completed and signed by a city licensed plumber, as well as the FSE owner or authorized representative, and submitted to the city. The original certification form must be submitted to: Greenville Planning Department Attn: FOG Program P.O. Box 897 Greenville, MS 38702-0897 (g) Failure of a grease interceptor certification or grease trap certification: The FSE owner or authorized representative is responsible for including detailed "corrective action response" information on the Annual Grease Interceptor Certification and Construction Inspection Form (Attachment B), or the Annual Grease Trap Certification and Construction Inspection Form (Attachment C) that is submitted to the city. If necessary, additional pages may be attached to the certification form. At a minimum, the "corrective action response" information must include the reason for the failed certification, what corrective action will be taken to correct the problem, and the date the corrective action will be completed. The Greenville Planning Department will review the request and either approve or deny the corrective action response and/or schedule. The city will utilize the FOG Control Enforcement Response Guide (Attachment D) when determining fines and/or penalties for non-compliance issues. (h) FSEs shall observe BMPs for controlling the discharge of FOG from their facility. Examples of BMPs include: (1) Recycle waste cooking oil; dispose in grease recycle bin or container. Do not pour any grease into sinks, floor drains, or mop sinks. (2) Post "No Grease" signs above all kitchen sinks to remind employees. (3) "Dry wipe" and scrape into a trash container as much food particles and grease residue from pots, pans, and plates as possible. (4) Use strainers in sink drains and floor drains to prevent large food particles and containers from entering the sewer line. (5) If an oil or grease spill occurs, clean up using "dry" oil absorbent material or use ice to make grease solidify. Scoop up and dispose into a trash container. Do not wash oil or grease into drains. (6) Dispose of food items in the trash. Food waste grinder (i.e. garbage disposal) use is discouraged due to build-up of solids in the GCE which causes decreased efficiency and the need to increase pumping frequency of the GCE. (7) Educate and train all employees on grease control and preventing sewer pipe clogs and sewer overflows. (i) FSEs shall dispose of yellow grease in an approved container, or recycle container, and the contents shall not be discharged to any sanitary sewer line, storm water grate, drain or other conveyance. Yellow grease, or oils, poured or discharged into the FSE sewer lines or city's sewer system is a violation of this program and the city's Sewer Use Ordinance (Attachment L). (j) It shall be a violation of this program and, therefore, the Sewer Use Ordinance (Attachment L), to push or flush the non-water portion of GCE into the public sewer.

(Ord. No. 18-001, § I, 1-25-18)

Ask a question about Greenville law

Corpus searches the Greenville sections it holds and shows the ones that match, with their citations. Free, no sign-in.