§ 12-154. - Building requirements for a minimum noise level reduction of 30 decibels (dB).
The following are building requirements for a minimum noise level reduction of 30 decibels (dB): (1) the following provisions shall apply to exterior walls: a. masonry block units shall be equivalent in weight to minimum six-inch dense concrete block. At least one surface shall be painted or plastered. A furred interior wall is not required on the inside of masonry walls. b. siding-on-sheathing, stucco or brick veneer shall be installed on the outside of minimum four-inch nominal deep studs. c. interior wall surface of exterior walls shall be minimum ⅝-inch gypsum board or plaster installed on the inside of the wall studs. d. continuous sheathing as required by the Code shall cover the exterior side of the wall studs behind wood, asphalt or aluminum siding. The sheathing shall be minimum one-half-inch thick. The weight of the sheathing and facing shall be at least four psf. e. sheathing boards or panels shall be butted tightly and covered on the exterior with overlapping and airtight building paper. The top and bottom edges of the sheathing shall be sealed airtight. f. minimum two-inch insulation material shall be provided in the cavity space behind the exterior sheathing and between wall studs. Insulation may be glass fiber or mineral wool. g. brick veneer, masonry blocks or stucco walls shall be constructed airtight except as otherwise required by the Code. All surface joints shall be grouted or caulked airtight. h. penetration of wall by pipes or ducts shall be caulked or filled with mortar. (2) the following provisions shall apply to windows: a. single-glazed windows may be used if the window is fixed and if the glazing is acoustical glass with a laboratory sound transmission rating of minimum STC-35. b. glass of double-glazed windows shall be minimum ⅛-inch thickness. Panes of glass shall be separated by a minimum three-inch air space and shall not be equal in thickness. c. glass of triple-glazed windows shall be of standard manufacturers' width and separation. d. double- and triple-glazed windows shall contain fixed sash or efficiently weather stripped operable sash. The sash shall be rigid and weather stripped with an efficiently airtight material that is compressed airtight when the window is closed. e. glass of fixed-sash windows shall be set and sealed in an airtight nonhardening glazing compound or in a elastomer gasket. f. the perimeter of window frames shall be sealed airtight to the exterior wall construction. g. total area of glass of both windows and doors in sleeping spaces shall not exceed 20 percent of the net floor area. (3) the following provisions shall apply to doors: a. double-door construction is required for all door openings to the exterior. If doors are separated by a vestibule of three-foot minimum depth, each door shall be one and one-half-inch minimum solid core wood or metal-clad door. One door shall be weather stripped in an airtight manner. The other door shall be tightly fitted to the door frame or shall be weather stripped. b. if no vestibule is used, a 1¾-inch minimum solid core wood door may be used in series with a storm door. Both doors shall be weather stripped in an airtight manner. c. single-frame sliding glass doors shall not be used. The glass of double sliding doors shall be separated by a minimum four-inch airspace. Each sliding frame shall be provided with an efficiently airtight weather stripping material. d. glass of storm and sliding doors shall be minimum 3/16 -inch. Glass of double sliding doors shall not be equal in thickness. e. the perimeter of door frames shall be sealed airtight to the exterior wall construction. (4) the following provisions shall apply to roofs: a. roof sheathing shall be minimum ¾-inch thick continuous plywood. Spaced board-sheathing shall not be used. b. roof sheathing joints shall be sealed airtight and shall be covered with overlapping, airtight building paper. c. exposed roof decks shall be minimum two-inch thick wood or concrete, and the total weight of the roof construction shall be a minimum of 12 psf. (5) the following provisions shall apply to ceilings: a. a minimum one-half-inch thick gypsum board or plaster ceiling shall be provided below attic spaces or below the roof rafters or roof decks less than two inches thick and weighing less than 12 psf. b. the ceiling shall be a minimum of 12 inches below the roof sheathing. c. minimum two-inch thick glass fiber or mineral wool insulation shall be provided above the ceiling between joists. Insulation in attic spaces shall have no paper or foil covering on the face exposed to the attic. (6) the following ventilation requirements shall apply: a. mechanical ventilation shall be provided of a type and design to provide adequate environmental comfort with all doors and windows closed during all seasons. b. window and through-the-wall ventilation units shall not be used. c. vent openings in attic or crawl spaces shall be minimum in number and size. The openings shall be provided with five-foot-long transfer ducts containing at least one 90-degree elbow and internal acoustical lining. d. ventilation ducts connecting the interior space to the outdoor or attic space shall contain at least ten-foot-long internal duct lining plus one lined 90-degree elbow. e. duct lining shall be coated glass fiber duct liner of one-inch minimum thickness. f. operational vented fireplaces shall not be used. g. building heating units with flues or combustion air vents shall be located in a closet or room closed off from the occupied space by doors. h. doors to mechanical equipment areas shall be 1¾-inch minimum solid core wood or 20-gauge steel hollow metal and shall be fully weather stripped. (7) the following additional requirements shall apply: a. all sleeping spaces shall be provided with either carpeting or an acoustical ceiling. b. through-the-wall/door mailboxes shall not be used.
(Ord. No. 24439, § II, 4-3-12)
Ask a question about Oklahoma City law
Corpus searches the Oklahoma City sections it holds and shows the ones that match, with their citations. Free, no sign-in.