10.03.160 - Grease interceptor and grease trap use and maintenance requirements.
(a) All permittees shall be required to show proof of installation of appropriate GCDs. GCDs shall be maintained in efficient operating condition by periodic removal of the accumulated FOG. Each permittee shall be responsible for the proper removal and disposal by appropriate means of the captured FOG material. No such accumulated FOG shall be introduced into any building sewer or public sewer. (b) Each permittee shall be required to contract with a licensed waste hauler for periodic collection of accumulated FOG from the GCDs for the purposes of physically segregating and disposing of FOG. The collection maintenance period shall be as determined appropriate by the FOG manager and/or specified in the FOG permit. The FOG manager shall assign each FSE one of the following collection/maintenance frequencies: thirty days, sixty days, ninety days, one hundred twenty days, or one hundred eighty days and may increase or decrease the service frequency of the GCD as deemed necessary to maintain the GCD designed efficiency. (c) All existing and newly installed grease interceptors and grease traps shall be maintained in a manner consistent with a maintenance frequency approved by the FOG manager pursuant to this section. (d) No FOG that has accumulated in a grease interceptor shall be allowed to pass into any sewer system, storm drain, or public right-of-way during maintenance activities. (e) At any time, FSEs with GCDs may be required to submit data and information necessary to establish the maintenance frequency of the GCD. (f) The maintenance frequency for all FSEs with grease interceptors shall be determined as follows: (1) Grease interceptors shall be fully pumped out and cleaned (maintained) at a frequency such that the combined FOG and solids accumulation does not exceed twenty-five percent of the total design hydraulic depth of the grease interceptor ("25% Rule"). The 25% Rule ensures that the minimum hydraulic retention time and required available hydraulic volume is maintained to effectively intercept and retain FOG from wastewater discharged to the sewer system. (2) Unless another frequency has been specified by the FOG manager or in the FOG permit, all FSEs with grease interceptors shall ensure they are maintained not less than once every ninety days. (3) The maintenance frequency shall be adjusted when sufficient data has been obtained to establish an average frequency based on the requirements described in Subsection 10.03.160(f)(1) and other guidelines adopted pursuant to the FOG control program. The city may change the maintenance frequency at any time to reflect changes in actual operating conditions in accordance with the FOG control program. Based on the actual generation of FOG from the FSE, the maintenance frequency may increase or decrease accordingly. (4) The owner/operator of a FSE may submit a written request to the FOG manager seeking a change in the maintenance frequency at any time. The FSE is responsible for the burden of demonstrating that the requested change in frequency reflects actual operating conditions based on the average FOG accumulation over time, meets the requirements described in Section 10.03.160(f)(1), and is in full compliance with the conditions of its FOG permit and this chapter. Upon a determination by the FOG manager that the requested revision is justified, the FOG permit shall be revised accordingly to reflect the change in maintenance frequency. (5) If at any time the grease interceptor contains FOG and solids accumulation that does not meet the requirements described in Section 10.03.160(f)(1), the FSE shall be required to have the Interceptor serviced immediately such that all FOG, sludge, and other materials are completely removed. If deemed necessary, the FOG manager may also increase the interceptor maintenance frequency from the current frequency. Notice of any change to the maintenance frequency shall be given in writing to permittee by the FOG manager. (6) Wastewater, accumulated FOG, floating materials, sludge/solids, and other materials removed from grease interceptors shall be properly disposed of off-site by waste haulers in accordance with federal, state and/or local laws. (g) The maintenance frequency for all FSEs with grease traps shall be determined as follows: (1) The maintenance frequency for grease trap shall be established by the FOG manager, but at a minimum, grease traps shall be serviced every thirty days. The FOG manager may reduce or increase the service frequency based on the actual generation of FOG by the FSE and establish a new service frequency in accordance with Section 10.03.160(b). (2) The owner/operator of a FSE may submit a written request to the FOG manager seeking a change in the maintenance frequency at any time after the initial servicing frequency period established for a newly-permitted FSE has expired. The FSE is responsible for the burden of demonstrating that the requested change in frequency reflects actual operating conditions based on the average FOG accumulation over time, meets the requirements described in Section 10.03.160(f)(1), and is in full compliance with the conditions of its FOG permit and this chapter. Upon a determination by the FOG manager that the requested revision is justified, the FOG permit shall be revised accordingly to reflect the change in maintenance frequency. (3) If at any time the grease trap contains FOG or solids accumulation that exceeds the capacity of the grease trap, the FSE shall be required to have the grease trap serviced immediately such that all FOG, sludge, and other materials are completely removed. If deemed necessary, the FOG Manager may increase the grease trap maintenance frequency from the current frequency. Notice of any change to the maintenance frequency shall be given to permittee in the form of a written notice from the FOG manager. (4) FSEs on thirty-day grease trap servicing frequency schedules requiring more frequent servicing shall submit plans to the city's building division for the installation and use of a grease interceptor. Exceptions may be granted if there is inadequate space for the installation of a grease interceptor or there is inadequate slope for gravity flow between kitchen plumbing fixtures and the grease interceptor.
(Ord. No. 2363, § 4, 3-21-17)
Ask a question about Victorville law
Corpus searches the Victorville sections it holds and shows the ones that match, with their citations. Free, no sign-in.