Sec. 7-1.1. - Building restrictions within the fire district.
7.1.1 Types of construction permitted: Within the fire district, every building hereafter erected shall be either Type I, II, III, or IV, except as permitted in section 7.1.4. 7.1.2 Other specific requirements: 7.1.2.1 Exterior walls of buildings located in the fire district shall comply with the requirements in Table 601 of the International Building Code adopted in section 7-26 of the Code of the City of Charleston, except as required in section 7.1.2.6. 7.1.2.2 Every Group H occupancy shall be prohibited from location within the fire district. 7.1.2.3 Every building shall be fire protected throughout as specified for the various types of construction in Chapter 6 of the International Building Code. 7.1.2.4 Roof covering in the district shall conform to the requirements of Class A or B roof covering as defined in Section 1505 of the International Building Code. 7.1.2.5 Walls, floors, roofs and their supporting structural members shall be a minimum of 1-hour fire resistance rated construction. Exceptions: 1. Buildings of type IV construction. 2. Buildings equipped throughout with an automatic sprinkler system in accordance with section 903.3.1.1 of the International Building Code. 3. Automobile parking structures. 4. Buildings surrounded on all sides by a permanently open space of not less than 30 feet. 5. Partitions complying with Section 603.1(8) of the International Building Code. 7.1.2.6 Exterior load bearing walls of Type II buildings shall have a fire resistance rating of two (2) hours or more where such walls are located within thirty (30) feet (9144 mm) of a common property line or an assumed property line. Exterior non-load bearing walls of Type II buildings located within thirty (30) feet (9144mm) of a common property line or assumed property line shall have fire resistance ratings as required by Table 601 of the International Building Code, but not less than 1 hour. Exterior walls located more than thirty (30) feet (9144mm) from a common property line or an assumed property line shall comply with Table 601 of the International Building Code. Exception: In the case of one story buildings that are 2,000 square feet or less in area, exterior walls located more than 15 feet from a common property line or an assumed property line need only comply with Table 601 of the International Building Code. 7.1.2.7 Architectural trim on buildings located in the fire district shall be constructed of approved noncombustible materials or fire retardant treated wood. 7.1.2.8 Permanent canopies may extend over adjacent open spaces provided: 1. The canopy and its supports shall be of noncombustible material, fire retardant treated wood, Type IV construction, or of one (1) hour fire resistant rated construction. Exception: 1. Any textile covering for the canopy shall be flame resistant as determined in accordance with NFPA 701 after both accelerated water leaching and accelerating weathering. 2. Any canopy covering, other than textiles, shall have flame spread Index not greater than 25 when tested in accordance with ASTM E 84 in the form intended for use. 3. The canopy shall have at least one (1) long side open. 4. The maximum horizontal width of the canopy shall not exceed fifteen (15') feet (4572mm). 5. The fire resistance of exterior walls shall not be reduced. 7.1.2.9 Structures, except aerial supports twelve (12') feet (3658mm) high, or less, flag poles, water tanks and cooling towers, placed above the roof of any building within the fire district shall be of noncombustible material and shall be supported by construction of noncombustible material. 7.1.2.10 The use of plastics complying with Section 2611 of the International Building Code for signs is permitted provided the structure of the sign in which the plastic is mounted or installed is noncombustible. 7.1.2.11 Exterior plastic veneer is not permitted in the fire district. 7.1.3 Changes to buildings: 7.1.3.1 Existing buildings within the fire district: An existing building shall not hereafter be increased in height or area unless it is of a type of construction permitted for new buildings within the fire district or is altered to comply with the requirements of such type of construction. Nor shall any existing building be hereafter extended on any side, nor square footage or floors added within the existing building unless such modifications are of a type of construction permitted for new buildings within the fire district. 7.1.3.2 Other Alterations. Nothing in 7.1.3.1 shall prohibit other alterations within the fire district provided there is no change of occupancy that is otherwise prohibited and provided the fire hazard is not increased by such alteration. 7.1.3.3 Moving Buildings. Buildings shall not hereafter be moved into the fire district or to another lot in the fire district unless the building is of a type of construction permitted in the fire district. 7.1.4 Buildings located partially in the Fire District: Any building located partially in the fire district shall be of a type of construction required for the fire district, unless the major portion of such building lies outside of the fire district and no part is more than ten (10') feet (3048mm) inside the boundaries of the fire district. 7.1.5 Exceptions to restrictions in the Fire District: The preceding provisions of this section shall not apply in the following instances: 1. Temporary buildings used in connection with duly authorized construction. 2. A private garage used exclusively as such, not more than one (1) story in height, nor more than six hundred fifty (650 sq. ft.) square feet (60m 2 ) in area, located on the same lot with a dwelling. 3. Fences not over eight (8) feet (2438mm) high. 4. Coal tipples, material bins, trestles constructed of Type IV construction. 5. Water tanks and cooling towers conforming to 1509.3 and 1509.4 of the International Building Code. 6. Greenhouses less than fifteen (15) feet (4572mm) high. 7. Porches on dwellings not over one (1) story in height, and not over ten (10) feet (3048mm) wide from the face of the building, provided such porch does not come within five (5) feet (1524mm) of any property line. 8. Sheds open on a long side not over fifteen (15) feet (4572mm) high and five hundred (500) square feet (46m 2 ) in area. 9. One- and two-family dwellings when of a type of construction not permitted in the fire district may be extended twenty-five (25%) percent of the floor area existing at the time of inclusion in the fire district by any type of construction permitted by this Code. 10. Wood decks less than six hundred (600) square feet (56m 2 ) when constructed of two (2″) inch nominal wood, pressure treated for exterior use. 11. Wood veneers on exterior walls conforming to 1405.4 of the International Building Code. 12. Exterior plastic veneer complying with Section 2605.2 of the International Building Code where installed on exterior walls required to have a fire resistance rating not less than one (1) hour, provided the exterior plastic veneer does not exhibit sustained flaming as defined in NFPA 268. 7.1.6 Referenced standards: ASTM E 84 Test Methods for Surface Burning Characteristics of Building Materials. NFPA 268 Standard Test Method for Determining Ignitability of Exterior Wall Assemblies Using a Radiant Heat Energy Source. NFPA 701 Methods of Fire Test for Flame-resistant Textiles and Films. The above referenced standards are from latest editions of the following recognized codes within the City of Charleston as adopted and amended from time to time by the South Carolina Building Codes Council: International Building Code, International Fire Code, International Plumbing Code, International Mechanical Code, International Energy Conservation Code, and International Fuel Gas Code, International Residential Code, as published by the International Code Council, the National Electrical Code, as published by the National Fire Protection Association, and the Building Energy Efficiency Standards Act as adopted by statute.
(Ord. No. 1994-420, § 1, 12-6-94; Ord. No. 1999-186, § 1, 12-21-99; Ord. No. 2001-54, § 1, 5-29-01; Ord. No. 2015-126, § 1, 9-22-15)
Ask a question about Charleston law
Corpus searches the Charleston sections it holds and shows the ones that match, with their citations. Free, no sign-in.