§ 62.7 — Standards for the floodway fringe district
Code of Ordinances of the City of Huntsville, Alabama (Supp. No. 30 (codified through Ord. No. 26-196, adopted March 12, 2026) with enacted ordinances through Ord. No. 26-837 (September 24, 2026) applied from official council minutes and ordinance copies) · Huntsville Code of Ordinances, App. A, art. 62, § 62.7
Corpus is an independent public-information project, not the official City of Huntsville website. Stable reference: corpuslaw.us/code/0acf18d3-993e-4c42-98b4-06e821b5ab8f
62.7. - Standards for the floodway fringe district.
In all areas of the floodway fringe district designated as zone AE or AH, the following provisions are required: 62.7.1. Residential construction. New construction or substantial improvement of any residential structure shall have the lowest floor, including basement and garage, elevated to at least one foot above the base flood elevation. When solid foundation perimeter walls are used to elevate a structure, openings sufficient to facilitate the unimpeded movement of floodwater shall be provided in accordance with the standards of section 62.7.3 and must be certified as such to the manager of inspection by a registered engineer or architect. 62.7.2. Nonresidential construction. New construction or substantial improvement of any commercial, industrial or other nonresidential structure shall either have the lowest floor, including basement and garage, elevated to at least one foot above the base flood elevation or, together with attendant utility and sanitary facilities, be floodproofed to one foot above the base flood elevation so that the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. A registered engineer or architect shall certify that the design and methods of construction are in accordance with accepted standards of practice for meeting the provisions above and shall provide such certification to the manager of inspection that the standards of this subsection and section 62.13.6 are satisfied. 62.7.3. Elevated buildings. New construction of or substantial improvements to elevated buildings that include any fully enclosed area located below the lowest floor formed by foundation and other exterior walls below the base flood elevation shall be designed to preclude finished living space and to allow for the entry and exit of floodwaters to automatically equalize hydrostatic flood forces on exterior walls. (1) Designs for complying with this requirement must either be certified by a registered engineer or architect or meet the following minimum criteria: (a) Provide a minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding; (b) The bottom of all such openings shall be no higher than one foot above grade; and (c) Such openings may be equipped with screens, louvers, valves or other coverings or devices provided they permit the automatic flow of floodwaters in both directions; (2) Access to the enclosed area shall be the minimum necessary to allow for parking of vehicles (garage door) or limited storage of maintenance equipment used in connection with the premises (standard exterior door) or entry to the living area (stairways or elevator); and (3) The interior portion of such enclosed area shall not be partitioned or finished into separate rooms. 62.7.4. For new manufactured home parks and subdivisions for expansions to existing manufactured home parks and subdivisions; for existing manufactured home parks and subdivisions where the repair, reconstruction or improvement of the streets, utilities and pads equals or exceeds 50 percent of value of the streets, utilities and pads before the repair, reconstruction, or improvement commenced; for a manufactured home placed on a site in an existing manufactured home park or subdivision where a manufactured home has incurred substantial damage as a result of a flood; and for manufactured homes not placed in a manufactured park or subdivision, but which are permitted by the board of zoning adjustment, the following are required: (1) Stands or lots elevated on compacted fill so that the lowest floor of the manufactured home will be one foot above the base flood elevation. (2) Manufactured homes placed or substantially improved in an existing manufactured home park or subdivision may be elevated so that either: (a) The lowest floor of the manufactured home is elevated no lower than one foot above the level of the base flood elevation; or (b) The manufactured home chassis is elevated and supported by reinforced piers (or other foundation elements of at least an equivalent strength) of no less than 36 inches in height above grade. (3) Each stand or lot shall have proper surface drainage and shall be accessible to the manufactured home and prime mover or hauler. (4) All manufactured homes must be securely anchored to an adequately anchored foundation system to resist flotation, collapse and lateral movement. 62.7.5. All recreational vehicles placed on sites must either: (1) Be on the site for fewer than 180 consecutive days, be fully licensed and ready for highway use, be on its wheels or jacking system, be attached to the site only by quick disconnect type utilities and security devices, and have no permanently attached structures or additions; or (2) Meet all the requirements for new construction including the anchoring and elevation requirements of section 62.7.4(1) and (4) above. 62.7.6. A registered land surveyor shall submit data to the manager of inspection certifying that the elevation of the lowest floor of a structure in a floodway fringe district is in compliance with this article. This certification shall be submitted prior to the floor being placed.
(Ord. No. 98-189, § 1(62.7), 4-7-1998)
Ask a question about Huntsville law
Corpus searches the Huntsville sections it holds and shows the ones that match, with their citations. Free, no sign-in.