IECC ENERGY CODE AMENDMENT, TABLE R402.1.4, EQUIVALENT U-FACTORS
Boise City Code § 9-9-25
in effect9-9-25: IECC ENERGY CODE AMENDMENT, TABLE R402.1.4, EQUIVALENT U-FACTORS:
Repeal the row in Table R402.1.4 for climate zones "5 and Marine 4" and replace with the following:
TABLE R402.1.4
EQUIVALENT U-FACTORSa
Climate Zone | Fenestration U-Factor | Skylight U-Factor | Ceiling U-Factor | Frame Wall U-Factor | Mass Wall U-Factorb | Floor U-Factor | Basement Wall U-Factor | Crawl- Space Wall U-Factor
5 | 0.32 | 0.55 | 0.03 0 | 0.06 0 | 0.08 2 | 0.03 3 | 0.05 0 | 0.05 5
Footnotes published underneath Table R402.1.4 in the code are applicable.
(Ord. 42-20, 12-1-2020, eff. 1-1-2021)
Source: Boise City, Idaho, City Code and City Charter (American Legal Publishing, codelibrary.amlegal.com)URL: https://codelibrary.amlegal.com/codes/boise_id/latest/boise/0-0-0-10790Fetched: 11/1/2026