§ 10-542 — Basic Stormwater Management Design Criteria
Code of Ordinances of the City of Tyler, Texas (September 2026: including amendments through September 9, 2026) · Tyler City Code § 10-542
Corpus is an independent public-information project, not the official City of Tyler website. Stable reference: corpuslaw.us/code/0b8989bd-6d30-4c36-97dc-e75f76d06bb4
Sec. 10-542. Basic Stormwater Management Design Criteria
a. Minimum Best Management Practices The Best Management Practices to be included in the Stormwater Management Plan are shown in Table 10-542 “Post Construction Best Management Practices”. For each zoning class or land use designation, the minimum number and type of BMP required for the Stormwater Management Plan is shown. Table 10-542. Post Construction Best Management Practices | Allowed Best Management Practices | UDC Best Management Practices | Zoning/ Land Use Designation | | | Single Family/Two Family Residential | Multi- Family Residential | Office | Commercial | Industrial | Institutional | | | Minimum Number of BMPs required for each Zoning/ Land Use Designation | | | 4 | 11 | 11 | 11 | 11 | 11 BMP | (Refer to BMP Chart Guidelines) | | "X" Denotes UDC Required BMPs TYPE | | | "O" Denotes UDC pre-approved optional BMPs SC-1 | Rain Water Harvesting | | | | | | | SC-2 | Bioretention (Rain Garden) | | | | | | | SC-3 | Stormwater Planters/Planter Boxes | | | | | | | SC-4 | Downspout Drywell (Perforated Manhole) | | | | | | | SC-5 | Green Roof | | | | | | | SC-6 | Urban Forestry/ Preservation of existing tree canopy/Tree Planting | | | | | | | SC-6A | | Sec 10-295-Land-scaping- (d.) Required tree plantings. | | X | X | X | X | X SC-6B | | Sec 10-301-Trees-(f.)-Public Tree Care | | | | | | SC-6C | | Sec 10-302-Pre- Development Tree Buffers are required. | | X | X | X | X | X SC-6D | | Sec 10-303- Tree Preservation is required. | | X | X | X | X | X SC-6E | | Sec 10-305-(c.) Residential tree plantings are required | X | | | | | SC-6F | | Sec 10-320- Post-Development Tree Bufferyards are required. | | X | X | X | X | X SC-7 | Landscaping/Natural Landscaping | | | | | | | SC-7A | | Sec 10-295 Landscaping- (c.) Non- residential lots are required to have 15% landscaping (green area). | | X | X | X | | X | | Sec 10-295 Landscaping- (c.) Industrial lots are required to have 5% landscaping (green area). | | | | | X | SC-7B | | Sec 10-295 Landscaping- Residential Lots are required to have not more than 50% building coverage. | X | | | | | SC-7C | | Sec 10-296-Street Trees-Street parkways must be planted with grass, or groundcover. | X | X | X | X | X | X SC-7D | | Sec 10-296-Street Trees-Street trees are allowed in parkways. | O | O | O | O | O | O SC-7E | | Sec 10-297-Land- scaping- (f.) Lot surfaces must have sod or ground cover. | X | X | X | X | X | X SC-7F | | Sec 10-298-Irrigation- Irrigation required. | | X | X | X | X | X SC-8 | Xeriscaping | | | | | | | SC-9 | Soil Amendments/Alum Treatment | | | | | | | SC-10 | Green Parking | | | | | | | SC-11 | Porous Concrete/Asphalt | | | | | | | SC-12 | Modular Porous Paver System | | | | | | | SC-13 | Create Parking Lot Storm Water “Islands” | | | | | | | SC-13A | | Sec 10-299-Parking Lots- Landscaped islands are required in parking lots. | | X | X | X | X | X SC-14 | Alternative Turnaround | Fire Department allows alternate Turn-Around Designs according to Appendix D of IFC. | | O | O | O | O | O TC-1 | Dry Extended Detention Basin | Sec 10-473 Allows detention facilities. | O | O | O | O | O | O TC-2 | Multi-Purpose Detention Areas | | | | | | | TC-3 | Underground Detention | | | | | | | TC-4 | Underground Wet Vault | | | | | | | TC-5 | Wet Pond | | | | | | | TC-6 | Storm Water Wetland | | | | | | | TC-7 | Retention and Irrigation | | | | | | | TC-8 | Street Surface and Subsurface Storage | | | | | | | TC-9 | Infiltration Basin | | | | | | | TC-10 | Infiltration Trench | | | | | | | TC-11 | Open Sand Filters | | | | | | | TC-12 | Organic Filter | | | | | | | TC-13 | Underground Sand Filter | | | | | | | TC-14 | Soakage Trench (Variation of Infiltration Trench) | | | | | | | TC-15 | Semi-pervious Channel Paving | | | | | | | TC-16 | Interceptor Swales/Grass Channel/Vegetated Swale | | | | | | | TC-17 | Enhanced Swales | | | | | | | TC-18 | Grassed Filter Strips/Vegetated Buffer Strip | | | | | | | TC-19 | Open Conveyance Channel/Natural Drainage ways | | | | | | | TC-20 | Inlet Inserts | | | | | | | TC-21 | Water Quality Inlet - Gravity (Oil-Grit) Separator/Hydrodynamic Separator | | | | | | | TC-22 | Proprietary Structural Controls (Vortex hydrodynamic separators, catch basin media inserts) | | | | | | | TC-23 | Stream Restoration | | | | | | | TC-24 | Forest/Prairie/Meadow Restoration | | | | | | | TC-25 | Microbial Disinfection | | | | | | | TC-26 | Permanent Outlet Protection at Storm Sewer Outfall - Concrete Riprap | | | | | | | TC-27 | Permanent Outlet Protection at Storm Sewer Outfall - Stone Riprap (Dry) | | | | | | | TC-28 | Permanent Outlet Protection at Storm Sewer Outfall - Stone Riprap (Grouted) | | | | | | | TC-29 | Permanent Outlet Protection at Storm Sewer Outfall - Stone Riprap (Mortared) | | | | | | | SD-1 | Open Space Design/Cluster Development | | | | | | | SD-2 | Preserve Riparian Buffers / Use Buffers and Undisturbed Areas/Avoid Floodplains | Sec 10-472-(b.2) Dedication of floodplain as greenbelt is allowed. | O | O | O | O | O | O | | Sec 10-472-(c.1) Dedication of floodplain as reserved floodway easement is allowed. | O | O | O | O | O | O | | Sec 10-554 Floodplain Management | | | | | | SD-3 | Preserve Undisturbed Natural Areas | Sec 10-472-(b.2) Dedication of floodplain as greenbelt is allowed. | O | O | O | O | O | O | | Sec 10-472-(c.1) Dedication of floodplain as reserved floodway easement is allowed. | O | O | O | O | O | O SD-4 | Fit Design to the Terrain | Sec 10-492 Low Impact Development allows alternate paving, storm water conservation easements, permeable pavements, and island placement adjustments. | O | O | O | O | O | O SD-5 | Locate Development in Less Sensitive Areas | | | | | | | SD-6 | Reduce Limits of Clearing and Grading | | | | | | | SD-7 | Minimize Siting on Porous or Erodible Soils | | | | | | | SD-8 | Avoid Steep Slopes / Use Retaining Walls | | | | | | | SD-9 | Reduce Setbacks and Frontages | Sec 10-490 Allows Low Impact Development. | O | O | O | O | O | O SD-10 | Dedication of Linear Park | Sec 10-472-(b.2) Dedication of floodplain as greenbelt is allowed. | O | O | O | O | O | O | | Sec 10-472-(c.1) Dedication of floodplain as reserved floodway easement is allowed. | O | O | O | O | O | O SD-11 | Conservation Easements | | | | | | | SD-12 | Consider Creative Design (LEED, Smart Growth) | | | | | | | SD-14 | Narrower Roadway ROW | Sec 10-155 Right of Way Width- Allows cul-de- sacs and local residential streets to have only 55’ ROW. (Narrow right-of-way). | O | | | | | SD-15 | Narrower Residential Streets/Reduce Roadway lengths and widths | Sec 10-155 Street Construction- Allows cul-de-sacs and local residential streets to be only 28’ F-F. (Narrow streets). | O | | | | | SD-16 | Eliminating Curbs and Gutters/Use Vegetated Swales | Sec 10-162 Curb and Gutter-Curb and gutter not required in a subdivision with all lots greater than 2 acres | O | | | | | SD-17 | Modify Driveway Standards/Alternative Driveway Surfaces/Shared Driveways | Sec 10-380- Surfacing-(c.) Maximum Parking Areas. | | O | O | O | O | O SD-18 | Reduce the Parking Footprint/Shared Parking | | | | | | | SD-18A | | Sec 10-357-Parking Space Design- designs that minimize paved areas are allowed. | | X | X | X | X | X SD-18B | | Sec 10-362- Shared parking arrangements- arrangements that minimize paved areas are allowed. | | O | O | O | O | O SD-20 | Reduce Directly Connected Impervious Area/Drain Rooftop Runoff to Pervious Area | | | | | | | SD-21 | Reduce Building Footprints | | | | | | | SD-22 | Design of Fueling Areas | | | | | | | SD-23 | Design of Maintenance Bays and Docks | | | | | | | SD-24 | Design of Trash Storage Areas | Sec 10-340-Trash Enclosures are required. | | X | X | X | X | X SD-25 | Design of Vehicle Washing Areas | | | | | | | SD-26 | Design of Outdoor Material Storage Areas | | | | | | | SD-27 | Design of Outdoor Work Areas | | | | | | | SD-28 | Design of Outdoor Processing Areas | | | | | | | (Ord. No. 0-2017-69; 8/23/17) For stormwater management practices requiring run-off calculations, the designs will be based on the Subdivision Design Guidelines. In addition, if hydrologic or topographic conditions warrant greater control than that provided by the minimum control requirements, the City of Tyler reserves the right to impose any and all additional requirements deemed necessary to control the volume, timing, and rate of runoff. For site design feasibility, conveyance issues, pretreatment requirements, treatment/geometry conditions or other design criterion, refer to the Subdivision Design Guidelines. b. Maintenance Agreements If used and required by the City, stormwater treatment practices shall have an enforceable operation and maintenance agreement to ensure the system functions as designed. This agreement will include any and all maintenance easements required to access and inspect the stormwater treatment practices, and to perform routine maintenance as necessary to ensure proper functioning of the stormwater treatment practice. In addition, a legally binding covenant specifying the parties responsible for the proper maintenance of all stormwater treatment practices shall be secured prior to issuance of any permits for land disturbance activities. c. Non-Structural Stormwater Practices The use of non-structural stormwater treatment practices is encouraged in order to minimize the reliance on structural practices. These non-structural practices are explained in detail in the Subdivision Design Guidelines. (Ord. No. 0-2011-45; 6/8/2011)
Ask a question about Tyler law
Corpus searches the Tyler sections it holds and shows the ones that match, with their citations. Free, no sign-in.