For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 31-66 — APPENDIX AH - PATIO COVERS - amendments

Scottsdale Revised Code (Supp. No. 80: codified through Ordinance No. 4681, adopted July 1, 2025) · Scottsdale Revised Code § 31-66

Corpus is an independent public-information project, not the official City of Scottsdale website. Stable reference: corpuslaw.us/code/0d25706b-91c5-4ea1-b6e1-6e2c1fd1605a

Sec. 31-66. - APPENDIX AH - PATIO COVERS - amendments.

(a) A new Section AH103.3, Fire rating, is added to read as follows: AH103.3 Fire rating. All patio covers shall be protected with a one-hour fire-resistive wall and parapet where: 1. Combustible patio covers are less than 3 feet from the property line. 2. Non-combustible patio covers are less than 1 foot 6 inches from the property line. Exception: Where the one-hour fire-resistive wall and parapet are required, a one-hour roof-ceiling assembly may be substituted for the parapet if: a. The roof-ceiling framing members are parallel to the one-hour wall, and the one-hour roof-ceiling assembly extends at least 5 feet from wall. b. The roof-ceiling framing members are perpendicular to the one-hour wall, and the entire span of the framing is at least one-hour fire-resistive construction. c. Openings in the roof are at least 5 feet from the property line.

(Ord. No. 4575, § 1(Res. No. 12499, § 1(Exh. A)), 12-6-22)