§ 11-26 — Standards for subdivision proposals and other proposed development

Code of Ordinances, City of Tupelo, Mississippi (Supp. No. 15: codified through Ordinance of March 5, 2024 and Ordinance of June 4, 2024) · Tupelo Code of Ordinances § 11-26

Corpus is an independent public-information project, not the official City of Tupelo website. Stable reference: corpuslaw.us/code/0de1b2b3-db2c-4bd6-88bf-9c02d9b9d616

Sec. 11-26. - Standards for subdivision proposals and other proposed development.

(a) All subdivision proposals shall be consistent with the need to minimize flood damage; (b) All subdivision proposals shall have public utilities and facilities such as sewer, gas, electrical and water systems located and constructed to minimize flood damage; (c) All subdivision proposals shall have adequate drainage provided to reduce exposure to flood hazards; and (d) Base flood elevation data shall be provided for all new subdivision proposals and other proposed development (including manufactured home parks and subdivisions), which is greater than five (5) lots or five (5) acres, whichever is the lesser. (e) Where only a small portion of the subdivision lot or lots is in an 'A' Zone special flood hazard area inundated by one hundred (100) year flood with no base flood elevations determined and there is sufficient ground slope on the site to avoid possible flooding of structures in zone X areas determined to be outside five hundred (500) year floodplain. The floodplain administrator may waive the requirement for a study to determine the base flood elevations. (f) In order for the floodplain administrator to consider waiving the requirement of section 11-26(d) the applicant must provide an accurate topographic data and map for the lot or lots in question certified by a licensed land surveyor and/or professional civil engineer indicating sufficient detail to allow a thorough review by the floodplain administrator. (g) Each proposed parcel must have a designated buildable pad or site above the one (1) percent chance floodplain. The distance of the buildable pad or site above the one (1) percent chance floodplain shall depend on the slope of the ground and in accordance with the following table: Distance in feet from Zone A [one percent chance floodplain] | Minimum Slope from Zone A — one percent floodplain to ground level at pad 20 | 5% 30 | 3.33% 40 | 2.50% 50 | 2.0% 60 | 1.67% 70 | 1.43% 80 | 1.25% 90 | 1.11% 100 | 1.0% Residential and non-residential structures lowest floor elevation also must be elevated 1.5 feet above the ground level on the buildable pad or site. (h) The subdivider/applicant must comply with the following: (1) File restrictive covenants on the lot or lots prohibiting construction within the designated special flood hazard area and requirement for lowest floor elevation. (2) Place a statement on the face of the plat prohibiting construction in the designated area of special flood hazard.*

(Ord. of 2-2-10(1), § 2)

Ask a question about Tupelo law

Corpus searches the Tupelo sections it holds and shows the ones that match, with their citations. Free, no sign-in.