Sec. 49-1903. - Minimum design standards.

All lawn sprinkling systems designs shall meet the following minimum standards: (a) Prevention of overspray onto neighboring private property, public sidewalks, streets or any areas not under the control of the property owner where the system is installed. (b) Velocity shall not exceed five feet per second (fps) at any point within the system. (c) Static pressure at the point of connection (POC) shall not exceed 80 psig. (d) Operating pressures shall fall within the following ranges: (1) Fixed heads: 15—30 psig. (2) Rotary heads: 40—70 psig. (e) Head Spacing shall conform to the following specifications: (1) Areas greater than ten feet wide shall be designed in either a square or triangular pattern with minimum head to head coverage. (2) Areas less than ten feet wide shall be designed for minimum head to head coverage (exception: drip emitters or bubblers). (3) Matched precipitation rate shall be used when possible.

(Ord. No. 40524, § 1, 10-20-15)