25.06.110 - Standards involving base flood elevations in A zones, including Zones A, AE, and AO

In all special flood hazard areas and flood-prone areas as defined in subsection 25.09.012.B, where base flood elevation data has been provided under Section 25.06.050 or subsection 25.06.090.C, the standards of subsections 25.06.110.A through 25.06.110.F apply. A. Residential construction 1. In AE zones or other A zoned areas where the BFE has been determined or can be reasonably obtained, new construction and substantial improvement of any residential structure shall have the elevation of the lowest floor, including basements, at or above the flood protection elevation. 2. New construction and substantial improvement of any residential structure in an AO zone shall meet the requirements under Section 25.06.130. 3. For new construction and substantial improvement of any residential structure, fully enclosed areas below the lowest floor are: a. Prohibited; or b. Shall be used solely for parking of vehicles, building access, crawl space, or storage, and shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement shall be certified by a registered professional civil engineer or architect; or shall meet or exceed the following minimum criteria: 1) Have a minimum of two openings having a total net area of not less than 1 square inch for every square foot of enclosed area subject to flooding; 2) The bottom of all openings shall be no higher than 1-foot above the adjacent grade and located on the lowest sides of the structure that allows for the flow of water through the enclosed area or 1-foot above an elevated slab on grade, whichever is higher; 3) Openings may be equipped with screens, louvers, valves, or other coverings or devices provided that they permit the automatic entry and exit of floodwaters; and 4) A garage attached to a residential structure, constructed with the garage floor slab below the flood protection elevation, must be designed to allow for the automatic entry and exit of floodwaters. B. Commercial, industrial, or other nonresidential structure construction 1. In AE or other A zoned areas where the BFE has been determined or can be reasonably obtained, new construction and substantial improvement of any commercial, industrial, or other nonresidential structure shall: a. Have the elevation of the lowest floor, including basements, at or above the flood protection elevation; or b. Be dry floodproofed so that the structure below the flood protection elevation is watertight with walls substantially impermeable to the passage of water or dry floodproofed to the elevation required by ASCE 24, whichever is greater: 1) Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy; 2) Be certified by a registered professional engineer or architect that the design and methods of construction are in accordance with accepted standards of practice for meeting provisions of this subsection 25.06.110.B.1 based on their development and/or review of the structural design, specifications, and plans. Such certifications shall be provided to the official as set forth in subsection 25.06.070.C. 2. In an AO zone, the structure shall meet the requirements under Section 25.06.130. 3. For new construction and substantial improvement of any nonresidential structure that is not dry floodproofed per subsection 25.06.110.B.1.b, fully enclosed areas below the lowest floor that are usable solely for parking of vehicles, building access, or storage in an area other than a basement and which are subject to flooding shall be designed to: a. Automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement shall be certified by a registered professional engineer or architect; or shall meet or exceed the following minimum criteria: b. Have a minimum of two openings with a total net area of not less than 1 square inch for every square foot of enclosed area subject to flooding; c. The bottom of all openings shall be no higher than 1 foot above either interior or exterior adjacent grade; d. Openings may be equipped with screens, louvers, valves, or other coverings or devices; or a registered engineer or architect may design and certify engineered openings, provided that they permit the automatic entry and exit of floodwater; and e. A garage attached to an elevated or dry floodproofed nonresidential structure, constructed with the garage floor slab below the BFE, must be designed to allow for the automatic entry and exit of floodwaters. 4. Exception to elevation standards for overwater structures. New construction or substantial improvement on piers and wharves that existed on or before August 19, 2020, for commercial, industrial, or other nonresidential structures, shall meet FEMA's standard of BFE. FEMA's BFE is measured from the top of the deck of the pier or wharf. C. Critical facilities 1. Construction of new critical facilities shall be located outside the limits of the special flood hazard areas and outside the limits of all other flood-prone areas as defined in Chapter 25.09 where possible. 2. Construction of new critical facilities shall be permissible within special flood hazard areas and all other flood-prone areas as defined in Chapter 25.09 if no feasible alternative site is available. 3. New critical facilities constructed within special flood hazard areas and all other flood-prone areas as defined in Chapter 25.09 shall have the elevation of the lowest floor at or above the flood protection elevation at the site or to the height of the 500-year flood if available, whichever is higher. 4. Access routes to all critical facilities shall be elevated to or above the level of the base flood elevation to the extent possible. D. Manufactured homes. All manufactured homes to be placed or substantially improved shall be installed using methods and practices which minimize flood damage including: 1. Being elevated on a permanent foundation such that the elevation of the lowest floor of the manufactured home is at or above the flood protection elevation; and 2. Being securely anchored to an anchored foundation meeting the requirements of subsection 25.06.100.B. E. Recreational vehicles. Recreational vehicles placed on sites within special flood hazard areas or flood-prone areas as defined in subsection 25.09.012.B shall: 1. Be on the site for fewer than 180 consecutive days; or 2. Be fully licensed and ready for highway use, on their wheels or jacking system, attached to the site only by quick disconnect type utilities and security devices, and be without permanently attached additions; or 3. Meet the requirements for manufactured homes specified in subsection 25.06.110.D. F. If a project proponent proposes to permit encroachments upon the floodplain when a regulatory floodway has not been adopted or to permit encroachments upon an adopted regulatory floodway which will cause base flood elevation increases in excess of those permitted under paragraphs (c)(10) or (d)(3) of 44 CFR 60.3, the following standards apply: 1. The applicant shall apply to the Federal Insurance Administrator for conditional approval of such action prior to permitting the encroachments to occur and shall submit the following as part of its application: a. A request for conditional approval of map change and the appropriate initial fees or request an exemption, whichever is appropriate; b. An evaluation of alternatives which would not result in a base flood elevation increase above that permitted under paragraphs (c)(10) or (d)(3) of 44 CFR 60.3 demonstrating why these alternatives are not feasible; c. Documentation of individual legal notice to all impacted property owners within and outside of the community, explaining the impact of the proposed action on their property; d. Concurrence of the chief executive officer of any other communities impacted by the proposed actions; e. Certification that no structures are located in areas which would be impacted by the increased base flood elevation; f. A request for revision of base flood elevation determination according to the provisions of 44 CFR 65.6; and g. A request for floodway revision in accordance with the provisions of 44 CFR 65.7. 2. Upon receipt of the Federal Insurance Administrator's conditional approval of map change and prior to approving the proposed encroachments, the Director shall provide evidence to the Federal Insurance Administrator of the adoption of floodplain management ordinances incorporating the increased base flood elevations and/or revised floodway reflecting the post-project condition. 3. Upon completion of the proposed encroachments, the Director shall provide as-built certifications in accordance with the provisions of 44 CFR 65.3. The Federal Insurance Administrator will initiate a final map revision upon receipt of such certifications.

(Ord. 127410, § 2, 2026; Ord. 126536, § 2, 2022; Ord. 126113, § 2, 2020; Ord. 125292, § 1, 2017 [amended effective date of Ord. 125248]; Ord. 125248, § 61, 2017 [cross-reference update]; Ord. 124447, § 7, 2014; Ord. 121828, § 15, 2005 [reenacted B]; Ord. 121196, § 32, 2003; Ord. 121115, § 4, 2003; Ord. 118396, § 194, 1996 [department name change]; Ord. 116255, § 1, 1992; Ord. 114395, § 1, 1989.)

Ask a question about Seattle law

Corpus searches the Seattle sections it holds and shows the ones that match, with their citations. Free, no sign-in.