For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 30-55 — Standards for areas of shallow flooding (AO zones)

Code of Ordinances, City of Denton, Texas (Supp. No. 37, Update 1: codified through Ordinance No. 26-296 adopted March 24, 2026) · Denton City Code § 30-55

Corpus is an independent public-information project, not the official City of Denton website. Stable reference: corpuslaw.us/code/0fdb6d3e-dd76-4ec4-aa98-1c8960bc5ca6

Sec. 30-55. - Standards for areas of shallow flooding (AO zones).

Located within the areas of special flood hazard established in section 30-5 are areas designated as areas of shallow flooding, where the path of flooding is unpredictable and indeterminate; therefore, the following provisions apply: (1) All new construction and substantial improvements of residential structures shall have the lowest floor, including basement, elevated to the top of the curb of the nearest street plus the depth number specified in the community's FIRM. If the building site is not located adjacent to a street, the lowest floor, including the basement, must be elevated a minimum of one (1) foot, plus the depth specified on the community's FIRM, above the highest adjacent existing ground elevation of the site. Fill for landscaping around the elevated structure will be limited to provide adequate drainage capacity by utilizing channelization methods that adequately route the water through the property. (2) All new construction and substantial improvements of nonresidential structures shall: a. Have the lowest floor, including basement, elevated above the top of the curb of the nearest street plus the depth number specified on the FIRM; or b. Together with attendant utility and sanitary facilities, be completely floodproofed to or about that level referenced in subsection (2)a. of this section so that any space below that level is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. (3) A registered professional engineer or architect shall submit a certification to the city engineer that the standards of this section, as proposed in section 30-51(a)(1) are satisfied.

(Ord. No. 22-2064, § 2, 10-18-22)

Ask a question about Denton law

Corpus searches the Denton sections it holds and shows the ones that match, with their citations. Free, no sign-in.