Application submission requirements for preliminary plats.
Tampa City Code § 27-153.2.21
in effectSec. 27-153.2.21. - Application submission requirements for preliminary plats.
All applications for preliminary plat approval shall be submitted to the department in the required number of copies and shall include the information as specified in the subdivision review technical manual, provided that the department or other appropriate departments may waive or modify such submittal requirements if a determination is made that such information is currently available to the city or is otherwise unnecessary. All determinations to waive or modify submittal requirements shall be made at the preapplication conference. The application for preliminary plat approval shall include the following:
(a) Boundary drawing. A sketch showing a metes and bounds description of the property proposed to be platted, total acreage, existing easements, utilities, streets, general topography, floodplain and flood zone boundaries and other significant features existing at the time of submission;
(b) Legal description. A legal description of the property, including the citation and general description of any existing easements, covenants or other restrictions affecting the use and development of the property existing at the time of submission. The legal description shall include the total acreage of the parcel or tract of land to be platted;
(c) Vicinity map. A vicinity map at a convenient scale showing the site, including existing roads and waterways, street rights-of-way and street intersections on all four (4) sides;
(d) Development schedule and plan. A proposed development schedule indicating the approximate starting and completion dates for the entire project and any phases, complete with a plan identifying and describing such phases;
(e) Subdivision name. The name of the plat shall be shown in bold legible letters of uniform size and type, including the words "section," "unit," "replat," "amended," etc., although the latter need not be in bold letters of the same size as the basic name. The name of the subdivision shall be shown on each sheet included. Such name shall not be so similar to another recorded subdivision in the city or county so as to confuse their identities. Subdivision names are subject to approval by the city;
(f) Transportation analysis. A transportation analysis shall be prepared by a professional traffic engineer. The analysis shall include the total trips generated by the project and the distribution of the trips onto adjacent streets. Institute of traffic engineers (ITE) trip generation rates or another approved source shall be used as the basis for trip generation calculations. (Note: Required only if analysis not previously prepared in association with another development approval, i.e., DRI, rezoning, etc., approved for the same project.) This requirement may be waived if the transportation division determines that the transportation impact will not be significant. In addition, the detailed traffic analysis shall include, but not be limited to, the following:
(1) Level of service calculations at each project access point for both the a.m. and p.m. peak hours;
(2) A determination of need for auxiliary lanes;
(3) A determination of need for traffic signalization or other control devices;
(4) Other transportation factors as may be appropriate as determined by the city's transportation division, based upon generally accepted traffic engineering practices;
(g) Concurrency review for transportation. All submissions for preliminary plat review shall include an application for a concurrency management transportation review. The transportation division will determine if the proposed project is concurrent. If a project is found not to be concurrent, the developer will be advised to schedule a methodology meeting with the city's traffic engineer. When a project is in compliance with concurrency, a temporary certificate of concurrency will be issued upon approval of the construction drawings. The final certificate of concurrency will be issued upon recordation of the final plat. The final certificate of concurrency will be required to apply for all building permits;
(h) Preliminary plat. A preliminary plat prepared in accordance with and including the following information:
(1) Graphic standards.
a. Sheet size. Drawings shall be on one (1) or more sheets twenty-four (24) inches by thirty-six (36) inches in size. A three-inch margin shall be provided on the left edge and one-half-inch margin on the remaining three (3) edges of all sheets;
b. Scale. All plans shall be at a scale which is no smaller than one (1) inch equals one hundred (100) feet;
c. Dimensions. All dimensions shall be feet;
d. North arrow. All drawings shall have a north arrow pointing to zero degrees north; and
e. Title block. A title block shall be located in the lower right corner of the format of all sheets and shall contain the following information:
1. Subdivision name;
2. City, county and state;
3. Sheet number and total number of sheets;
4. Name, address and phone number of the responsible individual or professional; and
5. Preparation date and date of any revisions;
(2) Existing site conditions.
a. The location of the property with respect to adjoining development, together with the existing zoning on adjoining property and existing land uses adjacent to the property (one-hundred-foot band at a minimum);
b. The name, location and width of existing or platted streets and street rights-of-way within or contiguous to the site;
c. The size and approximate location of sewers, water mains, storm drains and other underground facilities within or in close proximity to the site;
d. The location and width of easements for all utilities, such as electric power lines, within and adjacent to the site;
e. Topographic contours at one-foot intervals (five-foot contours in areas of steep slope when authorized by the department of public works), based on mean sea level datum. Topographic information shall be furnished by USGS, SWFWMD or a certified land surveyor;
f. National flood insurance program's flood zone boundaries and categories;
g. The location of trees or tree groupings and watercourses and other significant natural features, which shall be by reference on an aerial photograph at a scale of not less than one (1) inch equals one hundred (100) feet and the location and gross acreage of all wetlands and jurisdictional areas; and
h. The location and nature of existing land uses, historic sites and structures, buildings and existing zoning;
(3) Subdivision design.
a. The location and approximate dimensions of all lots. All lots shall be numbered. In mixed-use developments, general designations of intended use shall be included;
b. The location, nature and intended purpose of any proposed easements, reservations or dedications;
c. The location and approximate dimensions of reserved or dedicated recreational open space, including the total acreage of open space;
d. The nature, location and approximate dimensions of any buffer or other areas;
e. The name, location, width and curve radii of all proposed streets and rights-of-way;
f. The nature, location and approximate dimensions of all sidewalks, pedestrian ways and bike ways;
g. The general location and method of the potable water source;
h. The general layout of the stormwater management system, designed to specifications of the city; and
i. The approximate location of any proposed security guard houses, entry walls, entry gates, fences, perimeter walls and street medians; and
(4) All other information reasonably required by the city.
(Ord. No. 89-261, § 2(35-52), 10-12-89; Ord. No. 91-89, §§ 15—17, 5-30-91; Ord. No. 96-241, § 25, 10-31-96; Ord. No. 2013-67, § 1(Exh. A), 5-16-2013)
Source: City of Tampa, Code of Ordinances and Charter and Related Laws (Municode Library, library.municode.com)URL: https://library.municode.com/fl/tampa/codes/code_of_ordinances?nodeId=COOR_CH27ZOLADE_ARTIIADGEPR_DIV8SUPR_SD1.2CEDOREET_S27-153.2.21APSUREPRPLFetched: 10/28/2026