§ 49-1206 — Vertical rainwater drains and piping

Omaha Municipal Code (Supp. No. 100, Update 2: codified through Ordinance No. 44760, enacted August 4, 2026) · Omaha Municipal Code § 49-1206

Corpus is an independent public-information project, not the official City of Omaha website. Stable reference: corpuslaw.us/code/108f69f3-84be-4ffc-993a-4f88953e8704

Sec. 49-1206. - Vertical rainwater drains and piping.

Vertical rainwater leaders having no more than a ten-foot horizontal run in an offset below the roof and terminating to daylight above grade shall be sized according to projected roof areas as follows: Table 49-1206 * Maximum Projected Area of the Roof for Vertical Size of Leader | Roof Area (ft 2 ) 2 | 960 3 | 2,930 4 | 6,130 5 | 11,530 6 | 17,995 8 | 38,660 * Based on a maximum rainfall rate of three inches per hour.

(Ord. No. 40524, § 1, 10-20-15)