16.12.130 - Amendments to the International Plumbing Code.
The following amendments, deletions, or additions to the 2024 Edition of the International Plumbing Code are adopted by reference, as fully as though copied into such Plumbing Code, and thereby made a part of the Plumbing Code.
A. Section 101.1 of the 2024 Edition of the International Plumbing Code is hereby amended by deleting Section 101.1 and substituting the following:
101.1 Title. These regulations shall be known as the Plumbing Code of Metro Nashville and Davidson County hereinafter referred to as "this code".
B. Sections 101.2 through 115.4 of the 2024 Edition of the International Plumbing Code are hereby amended by deleting Sections 101.2 through 115.4 in their entirety.
C. Section 201 of the 2024 Edition of the International Plumbing Code is amended by adding a new Section 201.5 and substituting the following:
201.5 Interchangeability with the International Codes. The International Building Code shall be construed to mean the 2024 International Building Code. The International Property Maintenance Code shall be construed to mean the Property Code of the Metropolitan Government. The International Mechanical Code shall be construed to mean the 2024 International Mechanical Code. The International Fuel Gas Code shall be construed to mean the 2024 International Fuel Gas Code. The International Plumbing Code shall be construed to mean the 2024 International Plumbing Code. The International Private Sewage Disposal Code shall be construed to mean the Subsurface Sewage Disposal Systems Code. The ICC Electrical Code shall be construed to mean the 2023 National Electrical Code.
D. Section 202 of the 2024 Edition of the International Plumbing Code is hereby amended by adding the definition of "Plumbing Official" as follows:
PLUMBING OFFICIAL — shall mean the Director of the Metropolitan Department of Codes Administration, his deputy or duly authorized representative.
E. Section 202 of the 2024 Edition of the International Plumbing Code is hereby amended by deleting the definition of "Code Official" and substituting the following:
CODE OFFICIAL — shall mean the Director of the Metropolitan Department of Codes Administration, his deputy or duly authorized representative.
F. Sections 305.4 and 305.4.1 of the 2018 International Plumbing Code are hereby amended by deleting Sections 305.4 and 305.4.1 and substituting the following:
305.4. Freezing. Plumbing fixtures, water, soil and waste pipes shall not be installed outside of a building, in attics or crawl spaces, concealed in outside walls, or in any other place subjected to freezing temperature unless adequate provision is made to protect such pipes from freezing by insulation or heat or both. Exterior water supply system piping shall be installed not less than eighteen (18) inches below grade.
305.4.1 Sewer depth. Building sewers that connect to private sewage disposal systems shall be a minimum of twelve (12) inches below finished grade at the point of septic connection. Building sewers shall be a minimum of twelve (12) inches below grade.
Exceptions: variations to sewer connection depth shall be allowed only in the event of the city sewer connection point being less than the above stated depth, or being at a depth that prevents for proper fall from the business or residence to the connection point. In these instances, PVC shall have a pipe stiffness of 300 PSI or greater to prevent deflection failure from external live load.
G. Section 312.3 of the 2024 International Plumbing Code is hereby amended by deleting Section 312.3 and substituting the following:
312.3 Drainage and vent air test. Plastic piping shall not be tested using air. An air test shall be made by forcing air into the system until there is a uniform gauge pressure of 5 psi (34.5 kPa) or sufficient to balance a 10-inch (254 mm) column of mercury. This pressure shall be held for a test period of not less than 15 minutes. Any adjustments to the test pressure required because of changes in ambient temperatures or the seating of gaskets shall be made prior to the beginning of the test period.
Exception: Air testing on plastic pipe shall be permissible when water is not readily available or when the temperature is forecast to be below 32 degrees. Test pressure shall be between 3 and 5 PSI pursuant to the manufacturers rating.
H. Section 410.4 of the 2024 Edition of the International Plumbing Code is hereby amended by deleting Section 410.4 and substituting the following:
410.4 Where businesses provide drinking water in a container free of charge, an ADA accessible bottle filling station with disposable cups, or an ADA accessible water dispenser with disposable cups, drinking fountains shall not be required in those businesses. In other occupancies where three or more drinking fountains are required, water dispensers shall be permitted to replace not more than 50 percent of the required number of drinking fountains.
I. 503.1 of the 2024 Edition of the International Plumbing Code is hereby amended by deleting Section 503.1 and substituting the following:
503.1 Cold water line valve. The cold water branch line from the main water supply line to each hot water storage tank or water heater shall be provided with a valve, located within 3 feet of the equipment and serving only the hot water storage tank or water heater. The valve shall not interfere or cause a disruption of the cold water supply to the remainder of the cold water system. The valve shall be provided with access on the same floor level as the water heater served.
J. Section 604.9 of the 2024 Edition of the International Plumbing Code is hereby amended by deleting Section 604.9 and substituting the following:
604.9 Water hammer. The flow velocity of the water distribution system shall be controlled to reduce the possibility of water hammer. A water-hammer arrestor shall be installed where quick-closing valves are utilized. Water hammer-arrestors shall be installed as per the plan design but at a minimum at all washing machines, dishwashers, standalone ice makers, and solenoid valves or as part of the engineered plan design. Water-hammer arrestors shall be installed in accordance with the manufacturer's instructions. Water-hammer arrestors shall conform to ASSE 1010.
K. Section 607.2 of the 2024 Edition of the International Plumbing Code is hereby amended by deleting Section 607.2 and substituting the following:
607.2 Hot or tempered water supply to fixtures. The developed length of hot or tempered water piping, from the source of hot water to the fixtures that require hot or tempered water, shall not exceed 100 feet. This distance can be measured in straight line of site from the source to the fixture. Recirculating system piping and heat-traced piping shall be considered to be sources of hot or tempered water.
L. Section 903.1.1 of the 2024 Edition of the International Plumbing Code is hereby amended by deleting Section 903.1.1 and substituting the following:
903.1 Stack required. Open vent pipes that extend through a roof shall be terminated not less than 12 inches (304.8mm) above the roof.
M. The 2024 Edition of the International Pluming code is hereby amended by deleting Appendix A in its entirety.
N. The 2024 Edition of the International Plumbing Code is hereby amended by deleting Appendix F in its entirety and replacing Appendix F as follows:
APPENDIX F REGULATIONS GOVERNING PRIVATE SEWAGE DISPOSAL SYSTEMS
The following regulations shall apply to the manufacture, sale, installation, repair, alteration, extension and relocation of all private sewage disposal systems under the jurisdiction of the Metropolitan Government of Nashville and Davidson County.
F101. APPROVED AND LIMITATIONS.
F101.1 ALLOWABLE USE. Septic tanks and soil absorption systems and other similar facilities may be constructed where no public sewerage system is available or is likely to become available within a reasonable time.
F101.2 PUBLIC SEWER CONNECTION. Private domestic sewage treatment and disposal systems shall be discontinued and adequately abandoned when public sewers become available to the building served.
F101.3 PERMISSION TO CONSTRUCT. No plumbing permit shall be issued for the installation of any septic tank or disposal field or for any individual or private sewage disposal system until satisfactory evidence of approval of such system, by the Metropolitan Department of Health, has been submitted to the Department of Codes Administration. On approved and recorded subdivisions, such notification consists of a letter to Codes Administration from the Health Department which covers each subdivided lot.
F101.4 PLANS AND SPECIFICATIONS.
F101.4.1 All manufacturers or distributors of mechanical sewage disposal units, filters, precast septic tanks or any other method of sewage disposal must submit detailed plans and specifications to the Director of Health of the Metropolitan Health Department, and receive approval prior to the manufacture and sale or installation of the product with the Metropolitan area of Nashville and Davidson County.
F101.4.2 Commercial and public buildings, such as but not limited to theaters, food dispensers, assembly halls, schools, churches, apartment buildings, motels, factories, mobile home parks, camp grounds and parks proposed to be constructed in an unsewered area, must submit detailed plans and specifications for the proposed sewage disposal system to the Sanitary Engineering Division of the Metropolitan Health Department for approval prior to any construction.
F101.4.3 The plans and specifications shall be submitted in triplicate and shall include the following:
F101.4.3.1 Detailed plan of the proposed septic tank or treatment tank and effluent disposal system showing building location, and with the distance labeled from building served to system, from system to well, lot line, lake, stream or other watercourse.
F101.4.3.2 The ground slope should be indicated and information submitted relative to the expected use and occupancy of the building to be served.
F101.4.3.3 Provide soil borings and percolation test data.
F101.4.3.4 There shall be maintained at the project site one set of plans bearing the Health Department's stamp of approval.
O. The 2024 Edition of the International Plumbing Code is hereby amended by adding Appendix G as follows:
Appendix G Governing Connections to Public Utilities
The Plumbing Code of Metro Nashville and Davidson County shall enforce all regulations required by State and Federal Law issued by Metro Water Services. Please refer to Water Development Services page on the Metropolitan Government website for the most up to date requirements.
(Ord. BL2025-898 § 2, 2025; Ord. BL2020-458 § 2, 2020; Ord. BL2019-95 § 2, 2020; Ord. BL2015-1145 § 11, 2015; Ord. BL2007-1390 § 14, 2007; Ord. BL2002-1142 § 17, 2002; Ord. 98-1445 §§ 48—50, 1998; Ord. 96-562 § 35, 1996; Ord. 95-1487 §§ 30—51, 1995; Ord. 92-118 §§ 6—8, 1992; Ord. 89-1001 § 1 (part), 1989; Ord. 89-828 §§ 1, 2, 1989; prior code § 33-1-28 (a) (part))