Sec. 341.304. - Test of building sewer.

The test of the building sewer shall be accomplished by installing a teebranch at the point of connection to the public sewer and inserting a test plug. The building drain shall be filled with water from the test plug to the level of a toilet on the first floor and the drain shall hold the water at this level for a period of ten minutes. In addition to the water test, a ball three-quarters of an inch less in diameter than the building sewer shall be passed through the drain from the last stack farthest from the street to the tee-branch installed at the public sewer connection.

(Ord. 71-342-174; Ord. 83-591-400, § 1; Ord. 86-58-24, § 3)