§ 25.08.410 — Exterior sound level limits
Seattle Municipal Code (Supp. No. 44: codified through Ordinance No. 127459, passed June 30, 2026) · Seattle Mun. Code ch. 25.08, subch. III, § 25.08.410
Corpus is an independent public-information project, not the official City of Seattle website. Stable reference: corpuslaw.us/code/134a885f-4b09-41b3-bcd2-6fc51d8c892d
25.08.410 - Exterior sound level limits
A. The exterior sound level limits are based on the Leq during the measurement interval, using a minimum measurement interval of one minute for a constant sound source, or a one-hour measurement for a non-continuous sound source. For sound sources located within the City, the exterior sound level limits are as shown in Table A for 25.08.410: Table A for 25.08.410 Exterior sound level limits District of sound source | District of receiving property Residential (dB(A)) (Leq) | Commercial (dB(A)) (Leq) | Industrial (dB(A)) (Leq) Residential | 55 | 57 | 60 Commercial | 57 | 60 | 65 Industrial | 60 1 | 65 1 | 70 Footnote for Table A for 25.08.410 1 Except the sound level limit from a sound source that originates on property within the Ballard Interbay Northend Manufacturing and Industrial Center (BINMIC) and is within 200 feet of a shoreline is 70 (dB(A)) (Leq) in both residential and commercial receiving property districts. B. During a measurement interval, Lmax may exceed the exterior sound level limits shown in subsection 25.08.410.A by no more than 15 dB(A).
(Ord. 126865, § 2, 2023; Ord. 122923, § 22, 2009; Ord. 106360, § 302, 1977.)
Ask a question about Seattle law