§ 13-112 — Exceptions and amendments
Code of Ordinances of the City of Montgomery, Alabama (Supp. No. 27: codified through Ordinance No. 4-2026, enacted March 5, 2026) · Montgomery City Code § 13-112
Corpus is an independent public-information project, not the official City of Montgomery website. Stable reference: corpuslaw.us/code/13886710-2bd8-4f6a-9fc8-901b392f7351
Sec. 13-112. - Exceptions and amendments.
That the following exceptions and amendments are hereby adopted and made in the Code referred to in section 13-111 above: A. That Appendix B, C, D, E, F, G, H, I, J, K and M, N of International Fire Code, 2021 edition, be adopted. B. Fire Apparatus Turnarounds International Fire Code, 2021 edition, shall be amended as follows: Section D107.1 One- or two-family dwelling residential developments. Developments of one- or two- Family dwellings where the number of dwelling units exceed 30 shall be provided with a Fire apparatus turnaround with at least 150 feet diameter and approved fire apparatus access Road in compliance with Montgomery Fire/Rescue. C. Open Flame Cooking Devices International Fire Code, 2021 Edition, shall be amended as follows: Section 308.1.4 Open Flame Cooking Devices. Charcoal Burners and other open flame devices shall not be Operated or stored on any balconies sprinklered or not sprinklered. Open flame devices shall Not be operated within 10 feet of combustible construction. D. Subsection (A) 102.4 Application of the Building Code. The provision of the International Building Code as adopted by the City Council and enforced by the City of Montgomery Building Department shall apply to matters of the design and construction of new structures, and any alterations, additions, changes in use or changes in the structures required by this code, which are within the scope of the International Building Code, 2018 edition, shall be made in accordance therewith. E. Amend the International Building Code, 2018 edition, Chapter 9, section 901.3 as follows: 901.3 Modifications. Persons shall not remove or modify any fire protection system installed or maintained under the provisions of this code or the International Fire Code without approval by both the Building Official and the Fire Code Official. F. The International Building Code (IBC), 2018 edition, at no time shall supersede the International Fire Code (IFC), 2021 edition, without the approval of the Montgomery Fire/Rescue Fire Chief. G. Violation Penalties International Fire Code 2021 Edition shall be amended as follows: Section 112.4 Persons who violate the provisions of this code or shall fail to comply with any of the requirements of the International Fire Code 2021 edition shall be administered with a reinspection fee. Once a fire inspection is conducted on a business the business owner has 30 days to be in compliance with the adopted fire code. After 30 days and fire code violations have not been corrected a reinspection fee shall be issued. Once 90 days has passed and fire code violations are not corrected the third reinspection fee shall be issued and the business owner shall appear before the next scheduled City Council Meeting to have their business license denied and/or revoked. Once a business license has been denied and/or revoked, they shall not be reinstated until the Montgomery City Council members have approved the reinstatement and all debts with the City of Montgomery have been satisfied though the Fire Marshal's Office. H. (Assemblies) That Assembly Group A-2 of the International Fire Code, 2021 edition, shall be amended to add Rental halls to the Group A-2 occupancy listed in Chapter 9, section 903.2.1.2. F 1. (Definitions) Assembly Group A-2. Group A-2 occupancy includes assembly uses intended for food and/or drink consumption including, but not limited to: a) Banquet halls/ Rental halls/ Event Centers b) Casinos (gaming areas) c) Night clubs d) Restaurants, cafeterias and similar dining facilities (Including associated commercial kitchens) e) Taverns and bars I. Any facility meeting requirements of 2018 IFC Group A-2 occupancy conducting business after the Bureau of Inspections scheduled work hours is considered an after-hours entertainment venue and shall be required to provide documentation showing a Life Safety Inspection was conducted by the Montgomery Fire/Rescue Bureau of Inspections within Ninety (90) days prior to renewing their business license. The Assembly shall provide a copy of said year inspection before the business license is renewed. Failure to comply may result in loss of business licenses and shall appear before the City Council for the reinstatement of license. J. (Fire Protection Systems) If any occupancy allowing any required life safety fire protection equipment to be disabled, per 2021 International Fire Code, Chapter 9, section 901.5.1, it shall be unlawful to occupy any portion of the building or structure until the required fire detection, alarm, and suppression systems have been tested and approved. H 1. Any occupancy found with disabled fire protection equipment shall have their occupant load reduced to zero (0), excluding maintenance personnel. If occupancy is found with disabled fire protection equipment, occupant must receive approval of fire protection systems from Montgomery Fire/Rescue Bureau of Inspections at which time the occupant load shall be reinstated.
(Ord. No. 59-2012, § III, 9-18-2012; Ord. No. 47-2017, § I, 5-2-2017; Ord. No. 36-2020, § I, 9-15-2020; Ord. No. 34-2023, § I, 8-15-2023; Ord. No. 3-2026, § I, 3-5-2026)
Ask a question about Montgomery law
Corpus searches the Montgomery sections it holds and shows the ones that match, with their citations. Free, no sign-in.
