§ 8-1-9 — POINT OF USE PROTECTION
Mesa City Code (Supp. No. 22: codified through Ordinance No. 5996, adopted March 9, 2026) · Mesa City Code § 8-1-9
Corpus is an independent public-information project, not the official City of Mesa website. Stable reference: corpuslaw.us/code/150ad54c-1e5c-4770-88c0-20425e7b2f64
8-1-9: - POINT OF USE PROTECTION
(A) All equipment or appliances connected to a customer water system will be subject to evaluation for cross-connection potential and the degree of hazard presented to the customer water system. The customer must install and maintain point of use backflow protection at each such connection, as required by this section. The customer must have the backflow prevention assembly tested annually and ensure that reports are submitted to the Department. (B) Backflow prevention assemblies must be installed no more than five (5) feet above finished floor level and be capable of being accessed for testing and maintenance, but may require the removal of an access panel, door or similar obstruction. (C) Copper pipe must not be used downstream of a point of use Backflow Prevention Assembly where water is carbonated, deionized, distilled, or treated by reverse osmosis. (D) Point of use reduced pressure assemblies must be installed with an air gapped drain line for the relief valve. This drain line must be as large, or larger than, the size of the RPA, and properly secured. The drain must be routed to a floor sink, mop sink, or other appropriate wastewater outlet. Flexible hose material is not permitted for use as a drain line. (E) Point of use connections not on the list below may also be evaluated by the Department based on the degree of hazard, which will dictate the backflow protection required at the point of delivery. Multiple uses downstream of a point of use backflow protection are prohibited, unless approved by the Department. Where approved by the Department, a single point of use backflow prevention assembly may be used to isolate a group of similar pieces of equipment, such as pedicure stations. The following list identifies the point of use backflow protection required for specific equipment and appliances: Description of Cross Connection | Acceptable Level of Protection Aquariums | AG, PVB, RPA, SVB Aspirators (medical) | AVB, PVB Autoclaves | RPA Automotive Hose Reels | PVB, RPA, SVB Autopsy and Mortuary Equipment | AVB, PVB, RPA Auxiliary Water Source | AG, RPA Baptismal Fonts | AG, PVB, RPA, SVB Bedpan Washers | AVB, PVB Boiler Make Up Lines | RPA Boilers with Chemical Additives or Closed Loops | RPA Bottle Washer | RPA Car Wash Equipment | RPA Carbonated Beverage Dispensers | RPA Chemical and Soap Dispensers | AG, PVB, SVB Colonic Cleansing Equipment | AG, RPA Connection to Industrial Fluid Systems | AG, RPA Cooling Towers/Chillers | RPA, PVB Cuspidors | AVB, PVB Dental Chairs | RPA Dental Vacuum Pumps | RPA Dishwashers (Commercial) | AG, PVB, RPA, SVB, AVB Drain Line to Waste | AG Eyewash/Emergency Shower on Flexible Hose | AG, PVB, RPA, SVB Ice Cream, Yogurt, Gelato Makers (see water cooled condensers) | DCVA, RPA Ice Makers | DCVA, Dual Check Irrigation Systems | PVB, RPA Irrigation Systems with Chemical Addition | RPA Kitchen Equipment | AG, AVB, PVB, SVB Lab Equipment | AVB, PVB, RPA Model Trimmers | AG, PVB, RPA, SVB Non-Carbonated Beverage Dispenser | DCVA, Dual Check Pedicure Station | AG, PVB, RPA, SVB Pet grooming stations | AG, AVB, PVB, SVB Photo Processors | PVB, RPA, SVB Plating Tanks | RPA Reverse Osmosis Treatment | RPA Sewage Ejectors | AG Sewage Pumps | AG Sewer Pipe Connections | AG Shampoo Basins | AVB, PVB, SVB Specimen Tanks | AVB, PVB Steam Generator | RPA Sterilizers | RPA Swimming Pool Fill Lines | PVB, SVB, RPA Tanks, Vats, or Vessels | AG, PVB, RPA, SVB Thermalizer | RP Trap Primers | AG Warming Tables | AG, PVB, RPA, SVB Water Cooled Condensers, Equipment with | AG, RPA, Water Feature Fill Lines | PVB, RPA, SVB Water Vending Machines | RPA Yard Hydrants | RPA
(Ord. No. 5909, § 2, 12-9-24)
Ask a question about Mesa law
Corpus searches the Mesa sections it holds and shows the ones that match, with their citations. Free, no sign-in.