For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 10.08.020 — General POTW use requirements

Victorville, California, Municipal Code (Supp. No. 57: codified through Ordinance No. 2466, passed April 7, 2026) · Victorville Municipal Code § 10.08.020

Corpus is an independent public-information project, not the official City of Victorville website. Stable reference: corpuslaw.us/code/15afb247-f670-4e4b-802d-f80a9888d889

Sec. 10.08.020 - General POTW use requirements.

(1) Prohibited discharge standards. (a) General prohibitions. No user shall introduce or cause to be introduced into the POTW any pollutant or wastewater which causes pass through or interference. These general prohibitions apply to all users of the POTW whether or not they are subject to categorical pretreatment standards or any other national, state, or local pretreatment standards or requirements. (b) Specific prohibitions. No user shall introduce or cause to be introduced into the POTW the following pollutants, substances, or wastewater: (1) Pollutants which create a fire or explosive hazard in the POTW, including, but not limited to, wastestreams with a closed-cup flashpoint of less than 140 degrees F (60 degrees C) using the test methods specified in 40 CFR 261.21; (2) Wastewater having a pH level less than 5.0 or greater than 9.0, or otherwise causing corrosive structural damage to the POTW or equipment; (3) Solid or viscous substances in amounts which will cause obstruction of the flow in the POTW resulting in Interference but in no case solids greater than one-half inch in any dimension; (4) Pollutants, including oxygen-demanding pollutants (BOD, etc.), released in a discharge at a flow rate and/or pollutant concentration which, either singly or by interaction with other pollutants, will cause interference with the POTW; (5) Wastewater having a temperature greater than 140 degrees F (60 degrees C), or which will inhibit biological activity in the treatment plant resulting in interference, but in no case wastewater which causes the temperature at the introduction into the treatment plant to exceed 104 degrees F (40 degrees C); (6) Petroleum oil, non-biodegradable cutting oil, or products of mineral oil origin, in amounts that will cause interference or pass through; (7) Pollutants which result in the presence of toxic gases, vapors, or fumes within the POTW in a quantity that may cause acute worker health and safety problems; (8) Trucked or hauled pollutants, except at discharge points designated by the general manager in accordance with section 10.08.030(4) of this chapter; (9) Noxious or malodorous liquids, gases, solids, or other wastewater which, either singly or by interaction with other wastes, are sufficient to create a public nuisance or a hazard to life, or to prevent entry into the sewers for maintenance or repair; (10) Wastewater which imparts color which cannot be removed by the treatment process, such as, but not limited to, dye wastes, food and beverage processing wastes, and vegetable tanning solutions, which consequently imparts color to the treatment plant's effluent, thereby violating the district's NPDES or WDR permits; (11) Wastewater containing any radioactive wastes or isotopes except in compliance with applicable state or federal regulations; (12) Stormwater, surface water, ground water, artesian well water, roof runoff, subsurface drainage, swimming pool drainage, condensate, deionized water, noncontact cooling water, and unpolluted wastewater, unless specifically authorized by the general manager; (13) Sludges, screenings, or other residues from the pretreatment of industrial wastes; (14) Medical wastes, except as specifically authorized by the general manager in a WDP; (15) Wastewater causing, alone or in conjunction with other sources, the treatment plant's effluent to fail toxicity test; (16) Detergents, surface-active agents, or other substances which might cause excessive foaming in the POTW; (17) Fats, oils, or greases of animal or vegetable origin in concentrations greater than those set forth in the local limits adopted by district resolution; (18) Hazardous wastes as defined in 40 CFR Part 261. Pollutants, substances, or wastewater prohibited by this section shall not be processed or stored in such a manner that they could be discharged to the POTW. (2) National Categorical Pretreatment Standards. Users must comply with the categorical pretreatment standards found at 40 CFR Chapter I, Subchapter N, Parts 405—471, which standards are hereby incorporated into this chapter by this reference. (a) Where a categorical pretreatment standard is expressed only in terms of either the mass or the concentration of a pollutant in wastewater, the general manager may impose equivalent concentration or mass limits in accordance with subsections 10.08.020(2)(e) and (f). (b) When the limits in a categorical pretreatment standard are expressed only in terms of mass of pollutant per unit of production, the general manager may convert the limits to equivalent limitations expressed either as mass of pollutant discharged per day or effluent concentration for purposes of calculating effluent limitations applicable to individual industrial users. (c) When wastewater subject to a categorical pretreatment standard is mixed with wastewater not regulated by the same standard, the general manager shall impose an alternate limit in accordance with 40 CFR 403.6(e). (d) A CIU may obtain a net/gross adjustment to a categorical pretreatment standard in accordance with the following paragraphs of this section. (1) Categorical pretreatment standards may be adjusted to reflect the presence of pollutants in the industrial user's intake water in accordance with this section. Any industrial user wishing to obtain credit for intake pollutants must make application to the general manager. Upon request of the industrial user, the applicable standard will be calculated on a "net" basis (i.e., adjusted to reflect credit for pollutants in the intake water) if the requirements of paragraph (2) of this section are met. (2) Criteria. a. Either (i) the applicable categorical pretreatment standards contained in 40 CFR subchapter N specifically provide that they shall be applied on a net basis; or (ii) the industrial user demonstrates that the control system it proposes or uses to meet applicable categorical pretreatment standards would, if properly installed and operated, meet the Standards in the absence of pollutants in the intake waters. b. Credit for generic pollutants such as BOD, TSS, and oil, fat and grease should not be granted unless the industrial user demonstrates that the constituents of the generic measure in the user's effluent are substantially similar to the constituents of the generic measure in the intake water or unless appropriate additional limits are placed on process water pollutants either at the outfall or elsewhere. c. Credit shall be granted only to the extent necessary to meet the applicable categorical pretreatment standard(s), up to a maximum value equal to the influent value. Additional monitoring may be necessary to determine eligibility for credits and compliance with standard(s) adjusted under this section. d. Credit shall be granted only if the user demonstrates that the intake water is drawn from the same body of water as that into which the POTW discharges. The general manager may waive this requirement if it finds that no environmental degradation will result. (e) When a categorical pretreatment standard is expressed only in terms of pollutant concentrations, an industrial user may request that the general manager convert the limits to equivalent mass limits. The determination to convert concentration limits to mass limits is within the discretion of the general manager. The general manager may establish equivalent mass limits only if the industrial user meets all the conditions set forth in sections 10.08.020(2)(e)(1)a. through e., below. (1) To be eligible for equivalent mass limits, the industrial user must: a. Employ, or demonstrate that it will employ, water conservation methods and technologies that substantially reduce water use during the term of its WDP; b. Currently use control and treatment technologies adequate to achieve compliance with the applicable categorical pretreatment standard, and not have used dilution as a substitute for treatment; c. Provide sufficient information to establish the facility's actual average daily flow rate for all wastestreams, based on data from a continuous effluent flow monitoring device, as well as the facility's long-term average production rate. Both the actual average daily flow rate and the long-term average production rate must be representative of current operating conditions; d. Not have daily flow rates, production levels, or pollutant levels that vary so significantly that equivalent mass limits are not appropriate to control the discharge; and e. Have consistently complied with all applicable categorical pretreatment standards during the period prior to the industrial user's request for equivalent mass limits. (2) An industrial user subject to equivalent mass limits must: a. Maintain and effectively operate control and treatment technologies adequate to achieve compliance with the equivalent mass limits; b. Continue to record the facility's flow rates through the use of a continuous effluent flow monitoring device; c. Continue to record the facility's production rates and notify the general manager whenever production rates are expected to vary by more than 20 percent from its baseline production rates determined in subsection 10.08.020(2)(e)(1)c. Upon notification of a revised production rate, the general manager will reassess the equivalent mass limit and revise the limit as necessary to reflect changed conditions at the facility; and d. Continue to employ the same or comparable water conservation methods and technologies as those implemented pursuant to subsections 10.08.020(2)(e)(1)a. through e. of this chapter so long as it discharges under an equivalent mass limit. (3) When developing equivalent mass limits, the general manager: a. Will calculate the equivalent mass limit by multiplying the actual average daily flow rate of the regulated process(es) of the industrial user by the concentration-based daily maximum and monthly average standard for the applicable categorical pretreatment standard and the appropriate unit conversion factor; b. Upon notification of a revised production rate, will reassess the equivalent mass limit and recalculate the limit as necessary to reflect changed conditions at the facility; and c. May retain the same equivalent mass limit in subsequent WDP terms if the industrial user's actual average daily flow rate was reduced solely as a result of the implementation of water conservation methods and technologies, and the actual average daily flow rates used in the original calculation of the equivalent mass limit were not based on the use of dilution as a substitute for treatment pursuant to subsection 10.08.020(5). The industrial user must also be in compliance with subsection 10.08.130(3) regarding the prohibition of bypass. (f) The general manager may convert the mass limits of the categorical pretreatment standards of 40 CFR Parts 414, 419, and 455 to concentration limits for purposes of calculating limitations applicable to individual industrial users. The conversion is at the discretion of the general manager. (g) Once included in its permit, the Industrial user must comply with the equivalent limitations developed in this subsection 10.08.020(2) in lieu of the promulgated categorical standards from which the equivalent limitations were derived. (h) Many categorical pretreatment standards specify one limit for calculating maximum daily discharge limitations and a second limit for calculating maximum monthly average, or four-day average, limitations. Where such standards are being applied, the same production or flow figure shall be used in calculating both the average and the maximum equivalent limitation. (i) Any industrial user operating under a permit incorporating equivalent mass or concentration limits calculated from a production-based standard shall notify the general manager within two working days after the user has a reasonable basis to know that the production level will significantly change within the next calendar month. Any user not notifying the general manager of such anticipated change will be required to meet the mass or concentration limits in its permit that were based on the original estimate of the long term average production rate. (3) Local limits. (a) The general manager shall develop Local Limits pursuant to 40 CFR 403.5(c), to protect against pass through, interference and/or or impacts to biosolids reclamation or reuse. Such local limits shall be established by adoption of a resolution by the district board, following public notice to affected users and a public hearing thereon. Such local limits may be amended as necessary and revised by district resolution in the same manner. (b) Mass-based local limits. The district resolution shall establish local limits based on the total maximum allowable industrial load (MAIL) in pounds per day that can be allocated to all significant industrial users and other permitted industrial users. The general manager shall establish the industry specific allocation in the industrial user's WDP as a mass-based limit. It shall be unlawful for any significant industrial user or other permitted industrial user to discharge or cause to be discharged into the POTW any waste or wastewater that exceeds the total MAIL established or modified by the district's local limits resolution or the specific allocations set forth in the user's WDP. (c) The general manager may develop best management practices (BMPs), to be adopted by district ordinance or resolution, and thereafter included in WDPs to implement Local Limits and the requirements of section 10.08.020(1). (4) District's right of revision. The district reserves the right to establish, by ordinance, resolution or in WDPs, more stringent standards or requirements on discharges to the POTW consistent with the purpose of this chapter. (5) Dilution. No user shall ever increase the use of process water, or in any way attempt to dilute a discharge, as a partial or complete substitute for adequate treatment to achieve compliance with a discharge limitation unless expressly authorized by an applicable pretreatment standard or requirement. The general manager may impose mass limitations on users who are using dilution to meet applicable pretreatment standards or requirements, or in other cases when the imposition of mass limitations is appropriate.

(Ord. No. VWD-010, § 3(Exh. A), 10-21-14)

Ask a question about Victorville law

Corpus searches the Victorville sections it holds and shows the ones that match, with their citations. Free, no sign-in.