§ 7-69 — Construction and technical standards
Scottsdale Revised Code (Supp. No. 80: codified through Ordinance No. 4681, adopted July 1, 2025) · Scottsdale Revised Code § 7-69
Corpus is an independent public-information project, not the official City of Scottsdale website. Stable reference: corpuslaw.us/code/15ef2ea7-0a95-45f9-844f-6f401b60cae7
Sec. 7-69. - Construction and technical standards.
(a) General. The following general provisions are applicable: (1) A licensee shall place all cable and appurtenances "out of sight" to the maximum extent possible. "Out of sight" cable shall be either direct-buried or placed in an underground conduit system. Service vaults shall be flush to grade. Where the placement of some facilities and appurtenances below or flush to grade is not feasible, such facilities and appurtenances may be placed aboveground, but only if they are located so as to be as unobtrusive as technically possible consistent with the design of the cable system. Such aboveground facilities shall be screened as may be directed by the city. (2) In general, a licensee shall place all cable distribution plants below ground in those sections of the city where electric and telephone cables are below ground. In those sections of the city where the electric and telephone utilities maintain overhead distribution facilities, the poles supporting such facilities may be utilized by the licensee to the extent authorized by the utilities. Where such aerial construction is used, the licensee need not comply with the street boring requirement of section 7-70, subsection (b) providing the aerial crossings so established do not create conditions that are unsightly in the opinion of the city. Electric utility transmission poles shall not be used by the licensee for aerial distribution except in those specific locations where the licensee has received permission to use such poles from the city, with the further consent of the utility involved, after proving to the satisfaction of the city that no reasonable alternate route exists or alternative type of construction is feasible. (b) Compliance with construction and technical standards. The following provisions are also applicable: (1) A licensee shall construct, install, operate, and maintain its system in a manner consistent with all laws, ordinances, construction standards, governmental requirements, FCC technical standards, and detailed standards submitted by a licensee in its application, which standards are incorporated by reference herein. In addition, each licensee shall provide the city, upon request, with a written report of the results of the licensee's annual proof-of-performance tests conducted pursuant to FCC standards and requirements within five (5) days of completion of such reports. If the FCC eliminates its technical standards and the requirement for proof-of-performance tests, the city may impose substitutes or enforce existing license agreements containing such technical standards and proof-of-performance testing for the deleted requirements. (c) Construction and maintenance specifications. The following provisions are also applicable: (1) A licensee shall construct, install, and maintain its cable system in an orderly and workmanlike manner. The safety of the general public, the licensee's employees, the employees of the utilities, and all property shall be a primary objective whenever or wherever the licensee operates in the license area or in other areas where the licensee may locate equipment. (2) All cables and wires will be installed, to the maximum extent possible, parallel with electric and telephone distribution facilities. Multiple-cable configurations shall be arranged in parallel and bundled with due respect for engineering considerations. (3) A licensee shall be solely and completely responsible for the actions taken by any contractor, subcontractor, journeyman, consultant, or any other person employed to place, remove, maintain, repair, or relocate any of the licensee's facilities on public or private ways or easements as well as in or on public or private buildings or structures. The licensee shall give at least twenty-four (24) hours' prior written notice, to any public or private property owner whose property is affected, of its intent to place underground facilities by posting such notice on said property. Failure of the licensee to cause the prompt completion of such work, including restoration of property to its former condition, shall be deemed a violation of this chapter subjecting the licensee to the liquidated damages provided in section 7-45. (4) A licensee shall at all times comply with the current editions of the following publications as well as any subsequent editions or addenda: a. National Electric Safety Code (National Bureau of Standards). b. National Electrical Code (National Fire Protection Association). (5) A licensee shall comply with all of the following which may be applicable to its operations in the license area, as well as any additions or changes thereto: a. Laws, rules, regulations, and all recognized standards issued by the state. b. Laws, rules and regulations issued by the county. c. Ordinances of the city. d. FCC rules and regulations. e. Any other applicable federal, state, county, or city regulations. (6) In the event of conflicts in any of the above, the most restrictive as determined by the city shall apply to a licensee's operations in the license area. (7) A licensee shall have available at all hours personnel capable of responding to emergency conditions requiring immediate repair to any facilities owned by the state, county, city, or the gas, electric, and telephone utilities, as well as pipeline companies or similar industries. A licensee shall respond to location requests for location of its underground lines and facilities within forty-eight (48) hours. A licensee shall comply with Arizona Revised Statutes, title 40, chapter 2, article 6.3, Arizona Revised Statutes section 40-360.21 et seq., relating to underground utilities. (8) Any antenna structure used in the cable communication system shall comply with construction, marking, and lighting of antenna structures as required by the United States Department of Transportation. (9) All working facilities, conditions, and procedures used during construction, installation, and maintenance of the CATV system shall comply with the standards of the occupational safety and health administration. (10) RF leakage shall be checked at reception locations for emergency radio services to prove that no interference signal combinations are possible. Stray radiation shall be measured adjacent to any proposed or existing aeronautical navigation radio sites to prove that no interference to airborne navigational reception in the normal flight patterns is present. Any applicable FCC rules and regulations shall govern. (11) A licensee shall install and maintain equipment capable to providing standby power for headend, transportation, and trunk amplifiers for a period as specified in the license. (12) In all areas of the city where the cables, wires, and other like facilities of public utilities are relocated from aerial to underground, the licensee shall place its cables, wires, or other like facilities underground. Previously installed aerial cable shall be undergrounded in concert, and on a reasonable cost-sharing basis, with other utilities pursuant to the general ordinances of the city or applicable state law, or in the event that the telephone company decides to underground its facilities on a voluntary basis, unless the city grants an exception. (d) Electrical protection. The following provisions also are applicable: (1) To ensure the safety of the general public, as well as the licensee's workmen and the workmen of the utilities, and to protect property, adequate electrical protection is essential to the safe operation of the cable system. (2) A licensee shall at all times place such bonds as are required by the National Electrical Safety Code. In addition, with the concurrence of the electric and telephone utilities, such additional bonds shall be placed so as to conform to their existing or future bonding practices. This requirement shall apply to all aerial, underground, and direct-buried cable. (3) A licensee shall ground all service entrance cables and all service drops in accordance with the National Electrical Code, article 820. Driven ground rods or pipes, which are last-choice grounding devices, will be allowed only when there is no other option. If it becomes necessary to use a driven ground rod or pipe, it must be electrically connected to both the telephone and electric grounding electrodes, if present, by a No. 6 copper bond wire or equivalent.
(Ord. No. 1757, § 23, 8-19-85)
Ask a question about Scottsdale law
Corpus searches the Scottsdale sections it holds and shows the ones that match, with their citations. Free, no sign-in.