Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
40 C.F.R. § 443.12
in effectExcept as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
Effluent characteristic
Effluent limitations
Maximum for any 1 day
Average of daily values for 30 consecutive days shall not exceed—
Metric units (kg/cu m of runoff)
Oil and grease0.0200.015
pH(
1)(
1)
English units (lb/1,000 gal of runoff)
Oil and grease0.1670.125
pH(
1)(
1)
1 Within the range 6.0 to 9.0.