For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 62-44 — Standards for shallow flooding zones

Code of Ordinances, City of Jackson, Mississippi (Supp. No. 56: codified through Ordinance No. 2026-11(3), enacted February 24, 2026) · Jackson Code of Ordinances § 62-44

Corpus is an independent public-information project, not the official City of Jackson website. Stable reference: corpuslaw.us/code/17a14343-e6eb-4034-8113-96365c73e4d3

Sec. 62-44. - Standards for shallow flooding zones.

Located within the areas of special flood hazard established in Article 3, Section B, are areas designated as shallow flooding areas. These areas have flood hazards associated with base flood depths of one to three feet, where a clearly defined channel does not exist and the water path of flooding is unpredictable and indeterminate; therefore, the following provisions, in addition to the standards of Article 5, Sections A and B apply: (1) All new construction and substantial improvements of residential structures shall: a. Have the lowest floor, including basement, elevated to or above the highest adjacent grade at least as high as the depth number specified in feet on the flood insurance rate map plus a minimum of two feet. If no depth number is specified, the lowest floor, including basement, shall be elevated to no less than three feet six inches above the highest adjacent grade. (2) All new construction and substantial improvements of non-residential structures shall: a. Have the lowest floor, including basement, elevated to or above the highest adjacent grade at least as high as the depth number in feet specified on the FIRM plus a minimum of two feet. If no depth number is specified, the lowest floor, including basement, shall be elevated to no less than three feet six inches above the highest adjacent grade. b. Together with attendant utility and sanitary facilities be completely floodproofed to or above the highest adjacent grade at least as high as the depth number in feet specified on the FIRM plus a minimum of two feet so that any space below that level is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. Certification is required as stated in Article 5, Section B (2). (3) Adequate drainage paths shall be established around structures on slopes to guide floodwaters around and away from proposed structures.

(Ord. No. 2025-36(6), 10-7-25)

Ask a question about Jackson law

Corpus searches the Jackson sections it holds and shows the ones that match, with their citations. Free, no sign-in.