For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 31-20 — Machines for closed and semi-closed systems

Denver Revised Municipal Code (Supp. No. 147, Update 3: codified through Ordinance No. 0852-26, enacted July 13, 2026) · Denver Revised Municipal Code § 31-20

Corpus is an independent public-information project, not the official City of Denver website. Stable reference: corpuslaw.us/code/18c49a25-a51b-48fa-82b1-3a338a1f74f1

Sec. 31-20. - Machines for closed and semi-closed systems.

(a) Closed system. All closed systems shall complete all cleaning, drying and deodorizing processes entirely within vapor-tight machines, and shall be provided with ventilation in accordance with section 31-26(b) during loading and unloading to prevent the occurrence of excessive concentrations of solvent vapors in the machine service, or public access area while in operation. Such ventilation equipment shall operate automatically whenever the loading door is open. (b) Semi-closed system. All semi-closed systems shall be provided with mechanical ventilation in accordance with section 31-26(b) to prevent the occurrence of excessive concentrations of solvent vapors in the breathing zone of the employees or customers. This ventilation shall operate automatically at all times when the system, or any part thereof, is in use; except that when part of the ventilation is provided through the door of a vapor-tight extracting and drying unit, it shall operate automatically whenever the loading door is open.

(Code 1950, § 972.2-6)

Ask a question about Denver law

Corpus searches the Denver sections it holds and shows the ones that match, with their citations. Free, no sign-in.