Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).
40 C.F.R. § 469.14
in effectExcept as provided in 40 CFR 125.30 through 125.32 any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
Subpart A—Semiconductor BPT Effluent Limitations
Pollutant or pollutant property
Maximum for any 1 day
Average of daily values for 30 consecutive days
Milligrams per liter (mg/l)
TTO
11.37(
2)
pH(
3)(
3)
1 Total toxic organics.
2 Not applicable.
3 Within the range of 6.0 to 9.0.