Section 10.27A.550 Standby Power

A franchisee shall maintain equipment capable of providing standby power for the headends for a minimum of eight hours, and transportation and trunk amplifiers for a minimum of four hours. The standby power equipment shall engage automatically in the event of a power failure. A franchisee shall comply with all safety regulations to prevent standby generators from “back feeding” or otherwise powering the “dead” utility line.

Date Passed: Monday, June 4, 2007 Effective Date: Wednesday, July 11, 2007 ORD C34041 Section 1 (Recodification)