Pretreatment standards for existing sources (PSES).
40 C.F.R. § 420.95
in effectExcept as provided in 40 CFR 403.7 and 403.13, any existing source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for existing sources.
(a) Sulfuric acid (spent acid solutions and rinse waters)—(1) Rod, wire, and coil.
Subpart I
Pollutant or pollutant property
Pretreatment standards for existing sources
Maximum for any 1 day
Average of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Lead0.0005260.000175
Zinc0.0007010.000234
(2) Bar, billet, and bloom.
Subpart I
Pollutant or pollutant property
Pretreatment standards for existing sources
Maximum for any 1 day
Average of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Lead0.0001690.0000563
Zinc0.0002250.0000751
(3) Strip, sheet, and plate.
Subpart I
Pollutant or pollutant property
Pretreatment standards for existing sources
Maximum for any 1 day
Average of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Lead0.0003380.000113
Zinc0.0004510.000150
(4) Pipe, tube, and other products.
Subpart I
Pollutant or pollutant property
Pretreatment standards for existing sources
Maximum for any 1 day
Average of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Lead0.0009390.000313
Zinc0.001250.000417
(5) Fume scrubber.
Subpart I
Pollutant or pollutant property
Pretreatment standards for existing sources
Maximum for any 1 day
Average of daily values for 30 consecutive days
Kilograms per day
Lead0.03680.0123
Zinc0.04910.0164
Note: The above limitations are applicable to each fume scrubber associated with sulfuric acid pickling operations.
(b) Hydrochloric acid pickling (spent acid solutions and rinse waters)—(1) Rod, wire, and coil.
Subpart I
Pollutant or pollutant property
Pretreatment standards for existing sources
Maximum for any 1 day
Average of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Lead0.0009200.000307
Zinc0.001230.000409
(2) Strip, sheet, and plate.
Subpart I
Pollutant or pollutant property
Pretreatment standards for existing sources
Maximum for any 1 day
Average of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Lead0.0005260.000175
Zinc0.0007010.000234
(3) Pipe, tube, and other products.
Subpart I
Pollutant or pollutant property
Pretreatment standards for existing sources
Maximum for any 1 day
Average of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Lead0.001920.000638
Zinc0.002550.000851
(4) Fume scrubber.
Subpart I
Pollutant or pollutant property
Pretreatment standards for existing sources
Maximum for any 1 day
Average of daily values for 30 consecutive days
Kilograms per day
Lead0.03680.0123
Zinc0.04910.0164
Note: The above limitations shall be applicable for each fume scrubber associated with hydrochloric acid pickling operations.
(5) Acid regeneration (absorber vent scrubber).
Subpart I
Pollutant or pollutant property
Pretreatment standards for existing sources
Maximum for any 1 day
Average of daily values for 30 consecutive days
Kilograms per day
Lead0.2450.0819
Zinc0.3270.109
Note: The above limitations shall be applicable to the absorber vent scrubber wastewater associated with hydrochloric acid regeneration plants.
(c) Combination acid pickling (spent acid solutions and rinse waters)—(1) Rod, wire, and coil.
Subpart I
Pollutant or pollutant property
Pretreatment standards for existing sources
Maximum for any 1 day
Average of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Chromium0.002130.000852
Nickel0.001920.000638
(2) Bar, billet, and bloom.
Subpart I
Pollutant or pollutant property
Pretreatment standards for existing sources
Maximum for any 1 day
Average of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Chromium0.0009600.000384
Nickel0.0008640.000288
(3) Strip, sheet, and plate—continuous.
Subpart I
Pollutant or pollutant property
Pretreatment standards for existing sources
Maximum for any 1 day
Average of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Chromium0.006260.00250
Nickel0.005630.00188
(4) Strip, sheet, and plate—batch.
Subpart I
Pollutant or pollutant property
Pretreatment standards for existing sources
Maximum for any 1 day
Average of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Chromium0.001920.000768
Nickel0.001730.000576
(5) Pipe, tube, and other products.
Subpart I
Pollutant or pollutant property
Pretreatment standards for existing sources
Maximum for any 1 day
Average of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Chromium0.003220.00129
Nickel0.002890.000964
(6) Fume scrubber.
Subpart I
Pollutant or pollutant property
Pretreatment standards for existing sources
Maximum for any 1 day
Average of daily values for 30 consecutive days
Kilograms per day
Chromium0.08190.0327
Nickel0.07350.0245
Note: The above limitations shall be applicable to each fume scrubber associated with a combination acid pickling operation.