§ 15-1304 — SITE DESIGN DEVELOPMENT STANDARDS

Fresno Municipal Code (Supp. No. 55, Update 1 (online June 23, 2026): codified through Ordinance No. 2026-019) · Fresno Municipal Code § 15-1304

Corpus is an independent public-information project, not the official City of Fresno website. Stable reference: corpuslaw.us/code/1a733c74-bc5f-43ab-ba89-e40877141a69

SEC. 15-1304. - SITE DESIGN DEVELOPMENT STANDARDS.

A. Residential Transition Standards. Where an E District abuts a Residential District, the following standards apply: 1. Height. The maximum height within 40 feet of a Residential District is limited to 30 feet. The maximum height within 50 feet of a residential district is 40 feet. 2. Setbacks. a. Front and Street Side Yards. The front setback shall not be less than the required front yard on the abutting Residential District lot within 75 feet of the Residential District. b. Interior Side and Rear for the IL and IH Districts. The interior side and rear setback abutting a Residential District boundary shall be no less than 50 feet. c. Interior Side and Rear Setbacks for All Other Employment Districts. The interior side and rear setback abutting a Residential District boundary shall be 20 feet. 3. Landscape. See Table 15-2305-C.1, Required Landscape Buffers. 4. Screening. When a multi-story building is proposed and the second story or above is located within 50 feet of the side or rear yard of a single-unit lot, screening measures shall be applied to provide a reasonable degree of privacy. a. Screening measures include, but are not limited to, landscaping, alternate window and balcony placements, placing windows at least six feet from the floor of the interior of the unit, incorporating wing walls or louvers, using glass block or other translucent material, and other such methods. b. Sufficiency of Screening. The Review Authority shall determine the sufficiency of the proposed screening measures and may require additional measures. [image omitted; see the official code] FIGURE 15-1304-A: RESIDENTIAL TRANSITION STANDARDS—E DISTRICTS B. Exceptions to Maximum Height in Woodward Park Area. Within the geographic area that is hatched in Figure 15-1304-B, the maximum permitted building height may be increased to 120 feet. Such projects shall conform to the residential transition standards in Section 1304-A and shall be subject to a Planned Development Permit. [image omitted; see the official code] FIGURE 15-1304-B: EXCEPTIONS TO MAXIMUM HEIGHT IN WOODWARD PARK AREA C. Exceptions to Maximum Height in IL and IH Districts. Within the IL and IH Districts, uninhabited structures such as silos, cooling towers, and similar structures used for storage and manufacturing may exceed the maximum height prescribed in 15-1303-2 by no more than 40 feet. Height in excess of 100 feet for such structures is subject to a Conditional Use Permit. D. Enhanced Streetscape. Projects in O Districts which include buildings with a front setback of less than 15 feet shall provide the following streetscape enhancements: 1. Sidewalks shall be no less than 12 feet in width. 2. Street trees shall be provided as follows: a. Street trees should be located no more than three feet from the back of curb, and whenever possible should be aligned with other trees on the block. b. Street trees should generally be evenly spaced, no less than 20 feet apart, and not more than 40 feet apart. c. Whenever possible, trees should not be located directly in front of building entrances. d. Trees should be placed in tree wells measuring five feet by five feet. To maximize usable sidewalk area, tree wells shall be covered by grates of a design which is approved by the Director. Larger tree wells may be required by the Public Works Director for species requiring more space. The property owner shall assume maintenance responsibilities for the tree grates. e. Street trees should be deciduous, fast growing, drought tolerant, and should eventually form a tall canopy. Not more than one species should be planted per block. Whenever nearby pre-existing trees are in good condition and meet the intent of this section, new trees should be of the same species. 3. Pedestrian-scaled street lights shall be provided as follows: a. Street lights should be located no more than three feet from the curb, and whenever possible should be aligned with street trees and other lights on the block. b. Street lights should be generally evenly spaced, no less than 30 feet apart, and not more than 80 feet apart. Whenever possible, street lights should be no less than 15 feet from nearby street trees. c. Street lights should not be of the type commonly known as Cobra Heads or other types which are intended primarily for the illumination of the vehicular roadway. Lights should be ornamental and designed primarily for the illumination of the sidewalk. Whenever nearby pre-existing lights are in good condition and meet the intent of this section, new lights should be of the same type. Intersection safety lights shall be typical cobra-head design, while mid-block lighting should be ornamental and scaled for the pedestrian environment. Lighting shall meet Public Works standards. 4. Facades located with 15 feet of the public sidewalk shall be oriented to the street as follows: a. If there is a primary common building entrance which provides access to reception areas, elevators, stairs, and internal circulation, it shall face and be oriented to the street. If there is a yard between the sidewalk and the building, a paved path six feet in width shall be provided from the public sidewalk to the entrance. b. Direct entrances from the sidewalk in to individual establishments located along the street frontage shall be provided. If there is a yard between the sidewalk and the building, a paved path six feet in width shall be provided from the public sidewalk to the entrance. [image omitted; see the official code] FIGURE 15-1304-D-4: BUILDING ORIENTATION TO THE STREET 5. Exterior walls facing a front or street side lot line shall include windows, doors, or other openings with transparent glazing for at least 60 percent of the building wall area located between 2.5 and seven feet above the level of the sidewalk. Openings fulfilling this requirement shall have transparent glazing and provide views into work areas, display areas, sales areas, lobbies, or similar active spaces, or into window displays that are at least two feet deep. [image omitted; see the official code] FIGURE 15-1304-D-5: BUILDING TRANSPARENCY 6. Where buildings are located within two feet of a public sidewalk, the sidewalk shall be shaded by awnings or canopies as follows: a. Awning or canopy depth shall be no less than four feet and no more than 10 feet. b. Clearance shall be no less than eight feet and no more than 12 feet from the finished floor. E. Parking Setbacks. In the O, BP, and RBP Districts, parking shall be set back from the street facing lot line as shown in Table 15-1303-2, except as provided below: [image omitted; see the official code] FIGURE 15-1304-E.1: SURFACE PARKING SCREENING 1. Surface Parking. On lots less than 150 feet in width or depth, the parking setback may be reduced to six feet. This area shall be landscaped. Parking spaces shall be screened with a minimum three foot high berm, wall, or hedge, or combination thereof. 2. Partially Submerged and Podium Parking. Parking that is partially below the street grade may extend to the setbacks of the main structure. A maximum six feet of the parking structure height may extend above the street grade if screened along street facing elevations by foundation plant materials. Gates need not be screened. 3. Underground Parking. Parking that is fully underground and below the street grade may extend from property line to property line. 4. Carports. If proposed on a Major Street in the O or the BP Districts, carports: a. Should generally be located away from major streets. b. There shall be no more than six consecutive carport spaces parallel to major streets, with a minimum distance of 20 feet between every six carport spaces. 5. Driveways. The location and width of driveways shall be minimized; they are permitted only to provide access to garages, carports, and parking areas. Curb cuts are limited to one for every 50 feet of street frontage. F. Pedestrian Access. Within the O District, on-site pedestrian circulation and access must be provided according to the following standards. 1. To Streets. Direct and convenient access shall be provided to adjoining residential and commercial areas to the maximum extent feasible while still providing for safety and security. 2. To Transit. Safe and convenient pedestrian connections shall be provided from transit stops to building entrances. 3. To Circulation Network. Regular connections between on-site walkways and the public sidewalk and other planned or existing pedestrian routes shall be provided. An on-site walkway shall connect the primary building entry or entries to a public sidewalk on each street frontage. 4. Internal Connections. A system of pedestrian walkways shall connect all buildings on a site to each other, to on-site automobile and bicycle parking areas, and to any on-site open space areas or pedestrian amenities. 5. External Connections. In the O District, a system of pedestrian walkways shall connect the project site to adjacent Residential, Commercial, Mixed Use, Office districts as follows: a. If the adjacent Residential, Commercial, Mixed Use, and Office districts are undeveloped, stub connections shall be provided at a frequency of one per 600 feet. Upon the development of the adjacent parcels, any fencing or gates at the stubs shall be opened. b. If the adjacent Residential, Commercial, Mixed Use, and Office districts are developed and provide connection points via breaks in the perimeter wall/fence or stub streets, then the project shall provide pedestrian walkway connections at those locations. c. If the adjacent Residential, Commercial, Mixed Use, and Office districts are developed there are no possible connection points via breaks in the perimeter wall/fence, then the project shall not be required to provide connections. 6. Pedestrian Walkway Design. a. Walkways shall be a minimum of four feet wide, shall be hard-surfaced, and paved with concrete, stone, tile, brick, or comparable material. b. Where a required walkway crosses driveways, parking areas, or loading areas, it must be clearly identifiable through the use of a raised crosswalk, a different paving material, or similar method. c. Where a required walkway is parallel and adjacent to an auto travel lane, it must be raised or separated from the auto travel lane by a raised curb at least six inches high, bollards, or other physical barrier. G. Service Areas and Loading. Service and loading areas should be integrated with the design of the building and shall be screened from residential areas. Special attention shall be given when designing loading facilities in a location that is proximate to residential uses. Techniques such as block walls, enhanced setbacks, or enclosed loading can minimize adverse impacts to residents.

(Added Ord. 2015-39, § 1, eff. 1-9-16; Am. Ord. 2018-25, § 10, eff. 6-11-18; Am. Ord. 2025-024, § 26, eff. 7-27-25).

Ask a question about Fresno law

Corpus searches the Fresno sections it holds and shows the ones that match, with their citations. Free, no sign-in.