14.04.380 - Section R602.3.2, Exception and Table R602.3.2 of the 2025 Edition of the California Residential Code are amended to read as follows.

Exception: In other than Seismic Design Category D 0 , D 1 or D 2 , a single top plate used as an alternative to a double top plate shall comply with the following: 1. The single top plate shall be tied at corners, intersecting walls, and at in-line splices in straight wall lines in accordance with Table R602.3.2. 2. The rafters or joists shall be centered over the studs with a tolerance of not more than 1 inch (25 mm). 3. Omission of the top plate is permitted over headers where the headers are adequately tied to adjacent wall sections in accordance with Table R602.3.2. [image omitted; see the official code]

(Ord. No. 7461, § 5, 11-10-2025)