Sec. 5-112. - Exits generally.
Every Class A, Class B or Class D dance hall shall comply with the following requirements: (1) Exit passageways shall be not less than six (6) feet, eight (8) inches in height. (2) Stages shall have not less than one (1) exit on each side and such exits shall be not less than two (2) feet, six (6) inches in width. (3) Doors shall swing in the direction of exit travel, and if provided with latches, such latches shall be of a self-releasing type, such as panic bolts or similar devices which will permit the door to open when pressed against. No revolving door shall be permitted in any dance hall.
(Ord. No. 1796, § 1(10A-11), 4-12-66)