17.40.340 - Information required on plans.

A. General. In addition to the seismic analysis required in this part the person responsible for the seismic analysis of the building shall determine and record the information required by this section on the approved plans. B. Construction Details. The following requirements with appropriate construction details shall be made a part of the approved plans: 1. All unreinforced masonry walls shall be anchored at the roof and ceiling levels by tension bolts through the wall as specified in Table No. 3 of Section 17.40.330C or by an approved equivalent at a maximum anchor spacing of six feet. 2. a. All unreinforced masonry walls shall be anchored at all floors and ceilings with tension bolts through the wall or by existing rod anchors at a maximum anchor spacing of six feet. All existing rod anchors shall be secured to the joists to develop the required forces. Tests conforming to this part will be required to verify the adequacy of the embedded ends of existing rod anchors. b. Exception: Walls need not be anchored to ceiling systems that, because of their low mass and/or relative location with respect to the floor or roof systems, would not impose significant normal forces on the wall and cause out-of-plane wall failure. Calculations and drawings to verify this exception must be submitted as part of the analysis. 3. At the roof and all floor levels, the anchors nearest the building corners shall be combination shear and tension anchors located not more than two feet horizontally from the inside corners of the walls. 4. When access to the exterior face of the masonry wall is prevented by proximity of an existing building, wall anchors conforming to items 5(a) or (b) in Table No. 3 of Section 17.40.330C may be used. 5. Alternative devices to be used in lieu of tension bolts for masonry wall anchorage shall be tested as specified in Section 17.40.330H. 6. Diaphragm chord stresses of horizontal diaphragms shall be developed in existing materials or by the addition of new materials. 7. Where trusses and beams other than rafters or joists are supported on masonry independent secondary columns shall be installed to support vertical loads. 8. Parapets and exterior wall appendages not capable of resisting the forces specified in this part shall be removed, stabilized, or braced to ensure that the parapets and appendages remain in their original position. The maximum height of an unbraced, unreinforced masonry parapet above the lower of either the level of tension anchors or roof sheathing shall not exceed one and one-half times the thickness of the parapet wall. If the required parapet height exceeds this maximum height a bracing system designed for the force factors specified in the Table 23-J of the 1985 Uniform Building Code shall support the top of the parapet. Parapet corrective work must be performed in conjunction with the installation of tension roof anchors. 9. a. The minimum height of a parapet above the wall anchor shall be twelve inches. b. Exception: If a reinforced concrete beam is provided at the top of the wall, the minimum height above the wall anchor may be six inches. 10. All deteriorated mortar joints in unreinforced masonry walls shall be pointed with Type S or N mortar. Prior to any pointing, the wall surface must be raked and cleaned to remove loose and deteriorated mortar. All preparation and pointing shall be done under the continuous inspection of a special inspector. At the conclusion of the project, the inspector shall submit a written report to the building official setting forth the portion of work inspected. 11. Repair details for any cracked or damaged unreinforced masonry wall required to resist forces specified in this part. C. Existing Construction. The following existing construction information shall be made part of the approved plans: 1. The type and dimensions of existing walls and the size and spacing of floor and roof members. 2. The extent and type of existing wall anchorage to floors and roof. 3. The extent and type of any parapet bracing or other structural reinforcement to parts or portions of the building which were previously performed. 4. Accurately dimensioned floor plans and masonry wall elevations showing dimensioned opening, piers, wall thickness and heights, veneer locations and existing anchorages. 5. The locations of cracks or other damaged portions of unreinforced masonry walls requiring repair. 6. The type of interior wall surfaces and ceilings, and if reinstalling or anchoring of existing plaster is necessary. 7. The general condition of the mortar joints and if the joints need repointing. 8. The location of all in-place shear tests or core tests shall be shown on the floor plans and building wall elevations.

(Ord. 23766.)

Ask a question about San Jose law

Corpus searches the San Jose sections it holds and shows the ones that match, with their citations. Free, no sign-in.