25-34 Main Y, building trap, fresh air inlet.

A Y shall be placed in the main drain close to and inside the cellar wall. The branch of the Y shall be used to continue the house sewer and the end of the Y shall be used as a straight line for a cleanout to the street. Building (house) traps shall be installed on all sewer connections to the combined sewer systems or where specifically required by the plumbing code official. Each building trap, when installed, shall have two (2) cleanouts. A relief vent or fresh air intake shall be installed on the inlet side of the trap which need not be larger than one-half the diameter of the drain to which it connects. Such relief vent or fresh air intake shall be carried above grade and terminate in a screened outlet located outside the building. Fresh air inlets shall not have any other use.

(Ord. of 10-24-88; Ord. of 9-26-94; Ord. of 11-13-95; Ord. of 1-22-18(2))