Sec. 22.5-76. - Requirements for plumbing fixtures.
(a) Intent. To require reduced flow rates and consumption for plumbing fixtures, fixture fittings, and appliances installed within the city. Such high efficiency plumbing fixtures, fixture fittings, and appliances shall comply with the specifications below or with the United States. Environmental Protection Agency (EPA) WaterSense Program, where applicable. (b) Requirements for plumbing fixtures. (1) The city hereby adopts Section 8-31(A) of the Code of Miami-Dade County, Florida, which consists of the following local technical amendments to Table 604.4 of Chapter 6 (Plumbing) of the Florida Building Code. 604.4 Maximum flow and water consumption. The maximum water consumption flow rates and quantities for all plumbing fixtures and fixture fittings shall be in accordance with Table 604.4. Permit applications for new residential and commercial structures shall include high efficiency plumbing fixtures, fixture fittings and appliances as provided in Table 604.4. Such high efficiency plumbing fixtures, fixture fittings and appliances shall comply with the specifications in Table 604.4 or have received the U.S. Environmental Protection Agency (EPA) WaterSense Label. Exceptions: 1. Blowout design water closets having a maximum water consumption of three and one-half gallons (13 L) per flushing cycle. 2. Vegetable sprays. 3. Clinical sinks having a maximum water consumption of four and one-half gallons (17 L) per flushing cycle. 4. Service sinks. 5. Emergency showers. _____ TABLE 604.4 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS PLUMBING FIXTURE OR FIXTURE FITTING | MAXIMUM FLOW RATE OR QUANTITY (b) Lavatory, private | 1.5 gpm at 60 psi Lavatory, public, (metering) | 0.25 gallon per metering cycle Lavatory, public (other than metering) | 0.5 gpm at 60 psi Shower head (a) | 1.5 gpm at 80 psi Sink faucet | 1.5 gpm at 60 psi Urinal | Waterless or 0.5 gallon per flushing cycle Water closet | 1.28 gallons per flushing cycle (effective 1.28 gpf for dual flush systems) Dishwasher (residential) | 6.5 gallons per cycle or less (Energy Star/Water Sense Certified) (c) Dishwasher (commercial) | Less than 1.2 gallons per rack for fill and dump machines and less than 0.9 gallons per rack for all other types of machines Dishwasher (under the counter machines) | 1.0 gallon or less per rack for high-temperature machines and 1.7 gallons per rack for low temperature machines. Washing machine | Water factor of 8 or lower (Energy Star/Water Sense Certified) (c) gpm: gallons per minute psi: pounds per square inch For SI: 1 gallon = 3.785 L 1 gallon per minute = 3.785 L/m 1 pound per square inch = 6.895 kPa. (a) A handheld shower spray is a showerhead. (b) Consumption tolerances shall be determined from referenced standards. (c) Water factor in gallons per cycle per cubic foot. (2) The city hereby adopts Section 8-31(B) of the Code of Miami-Dade County, Florida, which consists of the following local technical amendments to Table P2903.2a of Chapter 29 (Residential) of the Florida Building Code. P2903.2a Maximum flow and water consumption. The maximum water consumption flow rates and quantities for all plumbing fixtures, fixture, fittings and appliances shall be in accordance with Table P2903.2a. Permit applications for new residential structures shall include high efficiency plumbing fixtures, fixture fittings and appliances as provided in Table P2903.2a. Such high efficiency plumbing fixtures, fixture fittings and appliances shall comply with the specifications in Table P2903.2a or have received the U.S. Environmental Protection Agency (EPA) WaterSense Label. TABLE P2903.2a MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES, FIXTURE FITTINGS AND APPLIANCES PLUMBING FIXTURE OR FIXTURE FITTING | PLUMBING FIXTURE OR FIXTURE FITTING MAXIMUM FLOW RATE (b) Lavatory faucet | 1.5 gpm at 60 psi Shower head (a) | 1.5 gpm at 80 psi Sink faucet | 1.5 gpm at 60 psi Water closet | 1.28 gallons per flushing (gpf) cycle (effective 1.28 gpf for dual flush systems) Dishwasher (residential) | 6.5 gallons per cycle or less (Energy Star/Water Sense Certified) (c) Washing machine | Water factor of 8 or lower (Energy Star/Water Sense Certified) (c)
(Ord. No. 14038, § 2, 12-9-21)
Ask a question about Miami law
Corpus searches the Miami sections it holds and shows the ones that match, with their citations. Free, no sign-in.