28.173 - MIXED USE AND NON-RESIDENTIAL BUILDING FORMS.
[image omitted; see the official code] Figure K12: Typical Commercial Block Building (1) Commercial Block Building. (a) Building Type. A multi-story building that is designed to support a mix of commercial or office uses on the ground floor with office, studio, lodging and/or residential units above. Buildings are typically designed with storefronts or arcades at ground floor. (b) Access and Entry. Principal entry to each ground floor unit shall be a direct entrance from the primary abutting street. Buildings shall be designed with storefronts, stoops or patios along at least forty percent (40%) of the front ground floor facade along the primary abutting street. Parking, loading and trash disposal may be accessed from an alley or through a side yard or rear yard drive serving one or more buildings. (c) Massing and Articulation. Maximum building length parallel to the primary abutting street shall not exceed one hundred sixty (160) feet without a significant articulation of the facade. Facades facing a public street shall be vertically articulated at a minimum interval of forty (40) feet. Entrances shall be provided at least every forty (40) feet along the primary abutting street. Figure K13: Typical Commercial Block Building Photo 1 [image omitted; see the official code] [image omitted; see the official code] [image omitted; see the official code] Figure K15: Typical Liner Building Photo (2) Liner Building. (a) Building Type. A specialized building, parallel to the street, which is designed to conceal an area such as a parking facility or loading dock. (Am. by ORD-24-00018, 3-20-24) (b) Access and Entry. The principal entry to each ground floor unit shall be a direct entrance from the primary abutting street. (c) Massing and Articulation. Maximum building length parallel to the primary abutting street shall not exceed three hundred (300) feet without a visual break such as a courtyard or recess. Minimum building depth is sixteen (16) feet. Facades facing a public street shall be vertically articulated at a minimum interval of forty (40) feet. Entrances shall be provided at least every forty (40) feet along the primary abutting street. [image omitted; see the official code] Figure K16: Typical Parking Building (3) Parking Building. (a) Building Type. A multi-story building specifically designed for parking. Other uses may be allowed above or below the parking level. Such a building may be developed with a liner building along the street frontage. (b) Access and Entry. Principal entry to each ground floor business or unit shall be a direct entrance from the primary abutting street. Vehicular entrance drives shall be located and designed to minimize interference with pedestrian movement. Vehicular entrances on secondary streets are encouraged. [image omitted; see the official code] Figure K17: Typical Parking Building Photo (c) Building Design. Upper floors shall be designed so that sloped floors typical of parking structures do not dominate the appearance of the facade. Windows or openings shall be provided that echo those of surrounding buildings. (d) Massing and Articulation. Maximum building length parallel to the primary abutting street shall not exceed (300) feet without a visual break such as a courtyard or recess. Facades facing a public street shall be vertically articulated at a minimum interval of forty (40) feet. [image omitted; see the official code] Figure K18: Typical Live-Work Building (4) Live-Work Building. (a) Building Type. Similar to townhouses in scale and detailing, but with a ground floor designed for small commercial, office and service establishments, often with storefront detailing. Buildings are typically placed close to the sidewalk, although a forecourt or patio design may be used to allow for outdoor seating space. (b) Access and Entry. Principal entry to each ground floor unit shall be a direct entrance from the primary abutting street. (c) Massing and Articulation. Massing, proportions and articulation of live-work buildings shall respond to existing residential buildings in their vicinity. Maximum building length along the primary abutting public street shall not exceed one hundred sixty (160) feet without a significant articulation of the facade. Facades facing a public street shall be vertically articulated at a minimum interval of forty (40) feet. (5) Residential/Commercial Conversion. (a) Building Type. A former residential building converted in whole or part to commercial or office use or courtyard; parking must be in the rear. The building form remains residential in character. (b) Access and Entry. Principal entry to each ground floor unit shall be a direct entrance from the primary abutting street. The residential form of the building shall generally be maintained. Accessibility may be improved by changes in entrance grade or other means. Figure K19: Typical Residential/Commercial Conversion [image omitted; see the official code] [image omitted; see the official code] [image omitted; see the official code] Figure K21: Typical Podium Building (6) Podium Building. (a) Building Type. A multi-story building in which the upper stories are stepped back from a lower base, to provide outdoor terraces, to avoid excessive shadowing of streets or public spaces, or to preserve important views. (b) Access and Entry. One or more ground floor entrances from the primary abutting street shall be provided. [image omitted; see the official code] Figure K22: Typical Podium Building Photo (c) Massing and Articulation. For lower-base facades, maximum building length along the primary abutting public street shall not exceed one hundred sixty (160) feet without a significant articulation of the facade. Lower-base facades facing a public street shall be vertically articulated at a minimum interval of forty (40) feet. (Am. by ORD-19-00025, 4-29-19) (7) Flex Building. (a) Building Type. A variable building type at least two stories in height, designed to accommodate a variety of uses, including combinations of office, retail, lodging, and/or residential. A principal entrance should be oriented to the primary abutting street. [image omitted; see the official code] Figure K23: Typical Flex Building (b) Access and Entry. One or more ground floor entrances from the primary abutting street shall be provided. (c) Massing and Articulation. Maximum building length along the primary abutting public street shall not exceed one hundred sixty (160) feet without a significant articulation of the facade. Facades facing a public street shall be vertically articulated at a minimum interval of forty (40) feet. (8) Industrial Building. [image omitted; see the official code] Figure K24: Typical Industrial Buildings (a) Building Type. A large open-floor-plate building that allows maximum flexibility in the types of uses accommodated. Buildings are typically characterized by a tall single story or first floor, and may be set on a raised base to facilitate industrial loading and unloading. (b) Access and Entry. One or more ground floor entrances from the primary abutting street shall be provided. [image omitted; see the official code] Figure K25: Typical Industrial Building Photo (c) Massing and Articulation. Facades facing a public street shall be vertically articulated at a minimum interval of 60 feet. (9) Free-Standing Commercial Building. (a) Building Type. A free-standing building of one or more stories designed to support a mix of commercial, retail, restaurant, service, office, or similar uses. The building may include multiple tenants. (b) Access and Entry. Buildings shall have a clearly defined, highly-visible customer entrance or entrances, marked by canopies, porticos, overhangs, arcades, facade recesses or projections, or similar features. (c) Massing and Articulation. Massing and articulation requirements shall be consistent with other applicable standards in this ordinance. [image omitted; see the official code] Figure K26: Typical Free-Standing Commercial Building (10) Civic or Institutional Building. (a) Building Type. This category includes a number of building types and sizes ranging from buildings with large floor plats and multiple levels to smaller-scaled structures Civic buildings can accommodate a variety of arts, culture, education, recreation, government, and public assembly purposes. A variety of architectural styles is acceptable. (b) Access and Entry. Buildings should have at least one entrance to a public street, courtyard, lawn, or other common open space. (c) Massing and Articulation. Facades facing a public street or public space shall be articulated vertically at a minimum interval of every forty (40) feet. Street-facing facades shall be positioned to accentuate vistas or directed views such as terminal views at the end of streets or adjacent to public spaces such as parks.
Ask a question about Madison law
Corpus searches the Madison sections it holds and shows the ones that match, with their citations. Free, no sign-in.