For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 5-637 — Permit procedures

Code of Ordinances of the City of Montgomery, Alabama (Supp. No. 27: codified through Ordinance No. 4-2026, enacted March 5, 2026) · Montgomery City Code § 5-637

Corpus is an independent public-information project, not the official City of Montgomery website. Stable reference: corpuslaw.us/code/1fd5582f-76b9-4fed-ad8d-927db02cfa13

Sec. 5-637. - Permit procedures.

Application for a floodplain development permit shall be made to the floodplain administrator, located in the engineering department, on forms furnished by the community prior to any development (any man-made change to improved or unimproved real estate, including, but not limited to, buildings or other structures, mining, dredging, filling, grading, paving, excavation, drilling operations, or storage of equipment or materials) in the SFHAs of the community, and may include, but not be limited to, the following: plans in duplicate drawn to scale showing the elevations of the area of development and the nature, location, and dimensions of existing or proposed development. Specifically, the following procedures and information are required for all projects in the SFHA or other designated floodplains within the jurisdiction of the City of Montgomery: (1) Application stage. Plot plans are to include: a. The BFEs where provided as set forth in division 4, sections 5-652 and 5-653; b. Boundary of the special flood hazard area (SFHA) and floodway(s) as delineated on the FIRM or other flood map as determined in division 2, section 5-617; c. Flood zone designation of the proposed development area as determined on the FIRM or other flood map as set forth in division 2, section 5-617; d. Elevation in relation to mean sea level (or highest adjacent grade) of the regulatory lowest floor elevation, including basement, of all proposed structures; e. Elevation in relation to mean sea level to which any non-residential structure will be flood-proofed; f. Design certification from a professional engineer, who is licensed to practice in the State of Alabama, or a licensed architect, who is registered to practice in the State of Alabama, that any proposed non-residential flood-proofed structure will meet the flood-proofing criteria of division 4, subsections 5-652(2) and 5-655(2); g. A foundation plan, drawn to scale, that shall include details of the proposed foundation system to ensure all provisions of this article are met. These details include, but are not limited to, the proposed method of elevation (i.e., fill, solid foundation perimeter wall, solid backfilled foundation, open foundation on columns/posts/piers/piles/shear walls) and description of any flood openings required in accordance with division 4, subsection 5-652(1) when solid foundation perimeter walls are used. h. Usage details of any enclosed areas below the lowest floor shall be described. i. Plans and/or details for the protection of public utilities and facilities such as sewer, gas, electrical, and water systems to be located and constructed to minimize flood damage. j. Description of the extent to which any watercourse will be altered or relocated as a result of a proposed development including current and proposed locations of the watercourse. An engineering report shall be prepared by a professional engineer, who is licensed to practice in the State of Alabama, on the effects of the proposed project on the flood-carrying capacity of the watercourse and the effects to properties located both upstream and downstream. The affected properties shall be depicted on a map or on the plot plan. k. Certification of the plot plan by a professional engineer or surveyor, who is licensed to practice in the State of Alabama, is required. (2) Construction stage. For all new construction and substantial improvements, the permit holder shall provide to the floodplain administrator an as-built certification of the regulatory floor elevation or flood-proofing level using appropriate FEMA elevation or floodproofing certificate immediately after the lowest floor or flood-proofing is completed. In addition: a. When flood-proofing is utilized for non-residential structures, said certification shall be prepared by professional engineer, who is licensed to practice in the State of Alabama, or architect, who is registered to practice in the State of Alabama. b. Any work undertaken prior to submission of these certifications shall be at the permit holder's risk. c. The floodplain administrator shall review the above referenced certification data submitted. Deficiencies detected by such review shall be corrected by the permit holder immediately and prior to further work being allowed. Failure to submit certification or failure to make the required corrections, shall be cause to issue a notice of violation and/or stop-work order for the project. d. The floodplain administrator or his/her designee shall make periodic inspections of projects during construction throughout the SFHAs within the jurisdiction of the community to ensure that the work is being done according to the provisions of this article and the terms of the permit. Members of the inspections/engineering department shall have a right, upon presentation of proper credentials, to enter on any premises within the territorial jurisdiction of the City of Montgomery during normal business hours of the community for the purposes of inspection or other enforcement action. e. The floodplain administrator may revoke and require the return of the floodplain development permit by notifying the permit holder in writing stating the reasons) for the revocation. Permits shall be revoked for any departure from the approved application, plans, and specifications; for refusal or failure to comply with the requirements of state or local laws; or for false statements or misrepresentations made in securing the permit. Any floodplain development permit mistakenly issued in violation of an applicable state or local law may also be revoked. (3) Finished construction. Upon completion of construction, a FEMA elevation certificate (FEMA Form 81-31 or equivalent), which depicts all finished construction elevations, must be submitted to the floodplain administrator prior to issuance of a certificate of occupancy. a. If the project includes a floodproofing measure, a FEMA floodproofing certificate must be submitted by the permit holder to the floodplain administrator. b. The floodplain administrator shall review the certificates) and the data submitted. Deficiencies detected by such review shall be corrected by the permit holder immediately and prior to certificate of compliance/occupancy issuance. c. In some instances, another certification may be required to certify corrected as-built construction. Failure to submit the certification or failure to make required corrections shall be cause to withhold the issuance of a certificate of compliance/occupancy. d. Documentation regarding completion of and compliance with the requirements stated in the permit application and with division 3, subsection 5-637(1) of this article shall be provided to the local floodplain administrator at the completion of construction or records shall be maintained throughout the construction stage by inspectors for the floodplain administrator. Failure to provide the required documentation shall be cause to withhold the issuance of a certificate of compliance/occupancy. e. All records that pertain to the administration of this article shall be maintained in perpetuity and made available for public inspection, recognizing that such information may be subject to the Privacy Act of 1974, as amended.

(Ord. No. 4-2026, 3-5-2026)

Ask a question about Montgomery law

Corpus searches the Montgomery sections it holds and shows the ones that match, with their citations. Free, no sign-in.