Field strength limits.
47 C.F.R. § 18.305
in effect(a) ISM equipment operating on a frequency specified in § 18.301 is permitted unlimited radiated energy in the band specified for that frequency.
(b) The field strength levels of emissions which lie outside the bands specified in § 18.301, unless otherwise indicated, shall not exceed the following:
Equipment
Operating frequency
RF Power generated by equipment (watts)
Field strength limit (uV/m)
Distance (meters)
Any type unless otherwise specified (miscellaneous)Any ISM frequencyBelow 500
500 or more25
25 × SQRT(power/500)300
1300
Any non-ISM frequencyBelow 500
500 or more15
15 × SQRT(power/500)300
1300
Industrial heaters and RF stabilized arc weldersOn or below 5,725 MHz
Above 5,725 MHzAny
Any10
(
2)1,600
(
2)
Medical diathermyAny ISM frequency
Any non-ISM frequencyAny
Any25
15300
300
UltrasonicBelow 490 kHzBelow 500
500 or more2,400/F(kHz)
2,400/F(kHz) × SQRT(power/500)300
3300
490 to 1,600 kHz
Above 1,600 kHzAny
Any24,000/F(kHz)
1530
30
Induction cooking rangesBelow 90 kHz
On or above 90 kHzAny
Any1,500
300
430
430
1 Field strength may not exceed 10 μV/m at 1600 meters. Consumer equipment operating below 1000 MHz is not permitted the increase in field strength otherwise permitted here for power over 500 watts.
2 Reduced to the greatest extent possible.
3 Field strength may not exceed 10 μV/m at 1600 meters. Consumer equipment is not permitted the increase in field strength otherwise permitted here for over 500 watts.
4 Induction cooking ranges manufactured prior to February 1, 1980, shall be subject to the field strength limits for miscellaneous ISM equipment.
(c) The field strength limits for RF lighting devices shall be the following:
Frequency (MHz)
Field strength limit at 30 meters (μV/m)
Non-consumer equipment:
30-8830
88-21650
216-100070
Consumer equipment:
30-8810
88-21615
216-100020
Notes
1. The tighter limit shall apply at the boundary between two frequency ranges.
2. Testing for compliance with these limits may be made at closer distances, provided a sufficient number of measurements are taken to plot the radiation pattern, to determine the major lobes of radiation, and to determine the expected field strength level at 30, 300, or 1600 meters. Alternatively, if measurements are made at only one closer fixed distance, then the permissible field strength limits shall be adjusted using 1/d as an attenuation factor.
Source: eCFRURL: https://www.ecfr.gov/api/versioner/v1/full/2024-07-01/title-47.xmlFetched: 7/26/2026