§ 25-12-114 — LOCAL AMENDMENTS TO THE ELECTRICAL CODE - TECHNICAL
Austin City Code (Supp. No. 174: codified through Ordinance No. 20260521-050, effective June 1, 2026) · Austin City Code § 25-12-114
Corpus is an independent public-information project, not the official City of Austin website. Stable reference: corpuslaw.us/code/207ee773-743a-48cb-8403-1058321e031f
§ 25-12-114 - LOCAL AMENDMENTS TO THE ELECTRICAL CODE - TECHNICAL.
The following provisions are local amendments to the 2026 Electrical Code. Each provision in this Section is a substitute for the identically numbered provision of the 2026 Electrical Code deleted by Section 25-12-111(B) or is an addition to the 2026 Electrical Code: 110.12 Mechanical Execution of Work. Neat and workmanlike. All electrical work shall be installed in a neat and workmanlike manner. In the Electrical Code, workmanlike manner means, but is not limited to, the following: 1. work that is skillfully installed consistent with the Electrical Code's requirements; 2. equipment, raceways, and cables are installed parallel or perpendicular to the building or structure's structural members; 3. when raceways or cables are grouped, the raceways and cables remain straight, parallel, or perpendicular to the building or structure's structural members; 4. each cable is cut to a length that prevents sagging, except when flexibility requires moderate sagging; and 5. each box, cabinet, enclosure, and device is installed level, parallel, or perpendicular to the building or structure's structural members. 210.5(C)(1) Conductor Identification. Color coding of conductors shall be consistent at all terminations, connections, and splice points as follows: (1) Single phase 120/240 volt wiring systems. (A) (B) (N) RED—BLACK—WHITE (2) Three phase four wire 120/208-volt wiring systems. (A) (B) (C) (N) RED—BLACK—BLUE—WHITE (3) Three phase three, and four wire 120/240-volt delta wiring systems. (A) (B) (C) (N) RED—ORANGE—BLACK—WHITE (4) 277/480-wye or 480-volt delta wiring systems. (A) (B) (C) (N) BROWN—YELLOW—PURPLE—GRAY Exception: NM Cable installed in one, two, or multifamily dwelling units. 680.13(1) Emergency switch for swimming pools. A clearly labeled emergency shutoff switch shall be installed to disconnect all ungrounded conductors for swimming pool equipment and underwater lighting systems. The switch shall be installed in a place that is readily accessible, within sight, and not less than five feet from the water's edge. The sign for the shut-off switch shall be capable of being read from a distance of 50 feet; shall be made of plastic, metal, or other durable material; and shall read "Emergency Shut Off. Exception: One- and two-family dwellings. 680.41 Emergency Switch for Spas and Hot Tubs. (A) A clearly labeled emergency shutoff switch shall be installed to disconnect all ungrounded conductors for spa or hot tub equipment and underwater lighting systems. The switch shall be installed in a place that is readily accessible, within sight, and not less than five feet from the water's edge. (B) The sign for the shut-off switch shall be capable of being read from a distance of 50 feet; shall be made of plastic, metal or other durable material; and shall read "Emergency Shut Off." Exception: One- and two-family dwellings.
Source: Ord. No. 20260423-048, Pt. 1, 9-1-26.
Ask a question about Austin law
Corpus searches the Austin sections it holds and shows the ones that match, with their citations. Free, no sign-in.
