§ 5-1-144 - WALL REINFORCEMENT IN BATHROOMS.
A dwelling unit located on the first story must be designed and constructed with a toilet room on the first story that contains a toilet and a lavatory and has reinforced walls that meet the following standards: (1) Lateral two-inch by six-inch or larger nominal wood blocking must be installed flush with stud edges of bathroom walls. (2) The centerline of the blocking must be 34 inches from and parallel to the interior floor level. (3) Blocking is not required in the portion of the toilet room wall located directly behind the lavatory.
Source: 1992 Code Section 7-1-184; Ord. 031106-12; Ord. 031211-11; Ord. 040115-45; Ord. 040610-7.