§ 34.507 — FIRE PROTECTION WATER SUPPLY
Madison General Ordinances (Rev. 28, Update 3: codified through ORD-26-00040, published August 3, 2026) · Madison General Ordinances § 34.507
Corpus is an independent public-information project, not the official City of Madison website. Stable reference: corpuslaw.us/code/21f169ac-0cfd-4244-ad2c-56e3273f7e15
34.507 - FIRE PROTECTION WATER SUPPLY.
The following requirements are in addition to the requirements found in IFC section 507: (1) Fire Protection Water Supply and Fire Hydrants. (a) Private fire hydrants and water mains shall be installed in accordance with NFPA 24, and Sec. 702.4 of the latest edition of the City of Madison Public Works Department "Standard Specifications for Public Works Construction." Private fire hydrants and water mains shall be maintained in accordance with NFPA 25. (b) Plans shall be submitted to the Chief for review to determine compliance with the applicable standards prior to the installation of private fire service mains and fire hydrants. The Chief shall act upon such applications within fifteen (15) days of receipt. Denials of such applications may be appealed to the Board. Exception: Plans for private fire service mains that do not supply a fire hydrant do not have to be submitted under this subdivision, if said plans for private fire service mains have been submitted, approved, and inspected by the City of Madison Building Inspection Division. (Am. by ORD-11-00152, 11-8-11) (c) Global Positioning System (GPS) coordinates of private fire hydrants shall be established and submitted to the Chief prior to final inspection. (Cr. by ORD-11-00153, 11-8-11) (d) All portions of the required fire apparatus access roads for newly constructed public buildings and places of employment and open storage of combustible materials shall be within five hundred (500) feet of at least two (2) fire hydrants. Hydrant spacing shall not exceed five hundred (500) feet between any two (2) hydrants. All portions of the exterior walls of newly constructed one- and two-family dwellings shall be within five hundred (500) feet of at least one (1) fire hydrant. On new streets hydrants shall also be located at the intersections and the end of dead end streets. Distances shall be measured along the path of the hose lay. Hydrants shall not be located where the hydrant is not accessible to fire apparatus. Private fire hydrants shall not be located in the public right of way. Hydrant requirements in accordance with this standard may be met with existing public or private hydrants. The Chief may approve alternative locations and spacing of fire hydrants provided hydrants meet the fire suppression tactical needs of the Fire Department. (Am. by ORD-11-00004, 1-12-11) (e) Fire hydrants shall not be located within twenty (20) feet of any building. Fire hydrants shall be no more than ten (10) feet and no less than five (5) feet from the curb or edge of the fire access road. Parking lot islands shall be a minimum of three and half (3½) feet from the center of the hydrants to the curb. (Am. by ORD-18-00033, 3-28-18, eff. 5-1-18) (f) Minimum Flow and System Design. 1. Private fire service mains serving fire hydrants shall be the same size as the public mains supplying the private water system unless hydraulically calculated to provide the minimum required flow and pressure in accordance with nationally recognized standards. In all cases, mains serving fire hydrants do not need to exceed ten (10) inches but shall be at least six (6) inches in diameter. Alternative designs, based on nationally recognized standards for calculating fire flow demands, may be approved by the Chief. If the minimum flow and pressure requirements cannot be supplied by a private water supply system, the owner may be required to install a water reservoir and pressure boosting system or a public water supply system and/or multiple points of connection to the public water main(s). 2. Control valves shall be provided to limit the number of private hydrants affected by maintenance, repair or construction. Valves shall be located at street intersections and at no more than eight hundred (800) feet intervals. Valves shall be provided in each hydrant lead. 3. All hydrants shall be positioned so the largest outlet faces the fire access road. 4. The center of the lowest outlet cap of fire hydrants shall be at least eighteen (18) inches above grade and not more than twenty-four (24) inches above grade. (g) Whenever the location of a fire hydrant may be obscured by its placement, or due to the placement of a building, structure, fencing, grade of land, vegetation, snow accumulation or other obstruction of vision, the Chief may require such fire hydrants to be identified and marked with above grade markers. Above grade markers are any devices, approved for use by the Chief, designed to promote and enhance the ready identification of fire hydrant locations. (h) No obstructions, including but not limited to power poles, trees, bushes, fences or posts may be located within five feet of a fire hydrant. Grade changes exceeding one and one-half (1½) feet are not permitted within five (5) feet of a fire hydrant or hydrant lead. (i) Property owners shall remove snow, vegetation or other material that has covered or obscured the view of the hydrant(s) located on their property, including the terrace area. (j) Fire hydrants shall be installed and in-service prior to combustible construction. (k) Private fire hydrants and water systems placed out of service or made inoperable for maintenance, repair or construction shall be covered with a durable and weather resistant bag which indicates the hydrant is not useable. The Fire Prevention Division shall be immediately notified when hydrants and/or systems are out of service. Fire hydrants and/or water systems shall be repaired and returned to service within forty-eight (48) hours except as otherwise approved by the Chief. (l) Annual inspection, testing and maintenance shall be submitted as required in Sec. 34.03, MGO. (2) Mobile Home Parks. Any mobile home park created or modified after August 1, 2002, shall have an approved fire protection water supply system. The system shall include water mains, fire hydrants and appurtenances in accordance with this code. Approved fire hydrants shall be installed so that every lot or structure in the mobile home park is within five hundred (500) feet of a hydrant. Materials and equipment used must meet the standards, rules and regulations of the Madison Water Utility.
(Secs. 34.507(1)(c) - (k) Renum. (d) - (l) by ORD-11-00153, 11-8-11)
Ask a question about Madison law
Corpus searches the Madison sections it holds and shows the ones that match, with their citations. Free, no sign-in.