§ 16-5.16.070 — Standards of construction
Victorville, California, Municipal Code (Supp. No. 57: codified through Ordinance No. 2466, passed April 7, 2026) · Victorville Municipal Code § 16-5.16.070
Corpus is an independent public-information project, not the official City of Victorville website. Stable reference: corpuslaw.us/code/22a8a4a5-2de1-42c5-936c-3e130616ab7f
Sec. 16-5.16.070: - Standards of construction
In all areas of special flood hazards the following standards are required: (a) Anchoring. (1) All new construction and substantial improvements shall be adequately anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy. (2) All manufactured homes shall meet the anchoring standards of Section 16-5.16.100. (b) Construction Materials and Methods. All new construction and substantial improvements shall be constructed: (1) With materials and utility equipment resistant to flood damage; (2) Using methods and practices that minimize flood damage; (3) With electrical, heating, ventilation, plumbing and air conditioning equipment and other service facilities that are designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding; (4) Within zones AH or AO, so that there are adequate drainage paths around structures on slopes to guide floodwaters around and away from proposed structures. (c) Elevation and Flood-proofing. (See definitions for "basement," "lowest floor," "new construction," "substantial damage" and "substantial improvement.") (1) Residential construction, new or substantial improvement, shall have the lowest floor, including basement: (i) In an AO zone, elevated above the highest adjacent grade to a height equal to or exceeding the depth number specified in feet on the FIRM, or elevated at least two feet above the highest adjacent grade if no depth number is specified; (ii) In an A zone, elevated to or above the base flood elevation, as determined by the City; (iii) In all other zones, elevated to or above the base flood elevation. Upon the completion of the structure, the elevation of the lowest floor including basements shall be certified by a registered professional engineer or surveyor, or verified by the City Building Inspector to be properly elevated. Such certification or verification shall be provided to the floodplain administrator. (2) Nonresidential construction, new or substantial improvement, shall either be elevated to conform with subsection (c)(1) of this Section or together with attendant utility and sanitary facilities: (i) Be flood-proofed below the elevation recommended under subsection (c)(1) of this Section so that the structure is watertight with walls substantially impermeable to the passage of water; (ii) Have structural components capable of restricting hydrostatic and hydrodynamic loads and effects of buoyancy; and (iii) Be certified by a registered professional engineer or architect that the standards of subsection (c)(2) of this Section are satisfied. Such certifications shall be provided to the floodplain administrator. (3) All new construction and substantial improvements with fully enclosed areas below the lowest floor (excluding basement) that are usable solely for parking of vehicles, building access or storage, and which are subject to flooding, shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwater. Designs for meeting this requirement must exceed the following minimum criteria: (i) Be certified by a registered professional engineer or architect; or (ii) Have a minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding. The bottom of all openings shall be no higher than one foot above grade. Openings may be equipped with screens, louvers, valves or other coverings or devices; provided, that they permit the automatic entry and exit of floodwaters. (4) Manufactured homes shall also meet the standards of Section 16-5.16.100.
Ask a question about Victorville law
Corpus searches the Victorville sections it holds and shows the ones that match, with their citations. Free, no sign-in.