D. - Sanitary Sewers.

(1) All gravity sewers shall be vitrified clay or epoxy lines asbestos cement sewer pipe conforming to A.S.T.M. standards, and installed in conformance with the specifications of the City's Public Works Department. (2) The minimum size of lateral sewer mains in residential areas shall be six (6) inches in diameter. Minimum grades shall be sufficient to produce a velocity of one and six-tenths (1.6) feet per second. (3) All outfall mains shall be of sufficient size to accommodate the maximum anticipated flow from the entire area tributary to the line as approved by the Director of Public Works. (4) Lift stations shall be furnished where necessary, of such size and design as approved by the Director of Public Works.